Users Manual

 

LoRaWAN Radar People Flow 

Sensor 

 

 

 

 

 

 PCR1-LR_V1_Useres_Manual-03_en / 06.04.2018 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

Summary of Contents for LoRaWAN Radar People Flow Sensor

Page 1: ...Users Manual LoRaWAN Radar People Flow Sensor PCR1 LR_V1_Useres_Manual 03_en 06 04 2018...

Page 2: ...ror status LED flashes quickly 3 Installation 4 Optimum placement detection range 4 Wall mounting 5 Ceiling mounting 5 Electrical connection 5 Device Setup 6 Payload 10 Payload examples 10 Payload dec...

Page 3: ...ice is logged on to the LoRaWAN network During this phase the LED flashes slowly After successful registration the LED goes off Operation LED off In normal operation all persons entering and leaving t...

Page 4: ...sensor People are counted from every direction Optimum placement detection range The device is equipped with a highly sensitive Doppler radar sensor Movements at an angle of 40 horizontal and 17 verti...

Page 5: ...to the walking direction Ceiling mounting The person counter can be mounted on a ceiling to count people passing underneath the device Please note the following The distance between the unit and the...

Page 6: ...15 Device Setup Install PCR1 Setup Tool The device can be configured with our free PCR1 Setup Tool for Windows 7 10 You can download it free from the following link https feed parametric ch pcr1 tools...

Page 7: ...Over the Air Activation configuration of the device 1 Connect PCR1 with a USB cable to your PC A virtual COM Port driver should be installed automatically by Windows 2 Start PCR1 Setup Tool select COM...

Page 8: ...vice Network registration will start immediately LED will go off if connection is successful Important Make sure the device is registered with your LoRaWAN network provider prior to this step 4 You ca...

Page 9: ...r LoRaWAN connection and checking device functions 1 Actual Peorpleflow counter that will be transferred with next transmit 2 Time until next transmit By pressing TX Now LoRa uplink will be enforced i...

Page 10: ...sons count 0000 ffff 0014 20 persons counted since last transmit dd Key DeviceDiagnostic data Device Diagnostics Data 0000000000 ffffffffff Parametric Device Diagnostic Data reserved for future use Pa...

Page 11: ...bin var num bin 0xFF if 0x80 num num 0x0100 num return num function hexToBytes hex for var bytes c 0 c hex length c 2 bytes push parseInt hex substr c 2 16 return bytes function DecodePCR1Payload dat...

Page 12: ...ront Distance to object 0 5 to 10 m Object speed 1 5 km h Distance between objects min 1 5 m Signal processing Adaptive FFT with automatic noise level cut off Mains frequency filtering Rating Supply V...