Summary of Contents for VS2.5

Page 1: ...VS2 5 Transmitter Installation Manual Document NHB VS2 5 INS Issue 11 0 2019 05 10 Status Standard...

Page 2: ......

Page 3: ...Fax 1 207 947 3693 Customer Service 24 hour support 1 877 628 8353 Canada USA only 1 902 823 5100 International Email support nautel com Web www nautel com The comparisons and other information provi...

Page 4: ......

Page 5: ...ion reference ground 3 1 Installing the RF feed line 4 1 Connecting ac power 5 1 Installing the ac entrance box 5 3 Installing program inputs 6 1 Planning 6 1 Connecting cables 6 1 Installing control...

Page 6: ...t supplied by Nautel 9 2 Parts ordering 9 2 Module replacement program 9 3 Tools for installation 9 3 Pre installation Installation assistance 10 1 Pre installation consulting 10 1 Installation and co...

Page 7: ...5 Installation Manual Issue 11 0 2019 05 10 Page vii Release control record Issue Date Reason 11 0 2019 05 10 Hardware Release 11 NARF66I 04 and NARF66I 05 Supports software version VS SW 5 2 and hig...

Page 8: ...VS2 5 Installation Manual Page viii Issue 11 0 2019 05 10...

Page 9: ...nical manual set and unpacking installation video installation kit and ancillary kit 4 Assemble your parts and tools For a list of required tools see Parts and tools on page 9 1 5 When you are ready t...

Page 10: ...ansmitter see page 2 1 Connecting to station reference ground see page 3 1 Installing control and monitoring wiring see page 7 1 Commissioning see page 8 1 Perform operational tasks Commissioning and...

Page 11: ...he USB device that also contains the technical documentation suite step by step video that shows how to unpack your VS2 5 and properly mount it in a cabinet VS2 5 Quick Start Guide full colour foldout...

Page 12: ...VS2 5 Installation Manual Mounting the transmitter Page 2 2 Issue 11 0 2019 05 10...

Page 13: ...inet 3 For information about grounding the lightning protection see the VS2 5 Pre Installation Manual For detailed information about lightning protection see the Recommendations for Transmitter Site P...

Page 14: ...11 0 2019 05 10 Figure 3 1 Station Reference Ground Strap Connection E1 1 4 threaded stud IMPORTANT Do not allow conductor to contact the transmitter or host cabinet chassis at any other point From S...

Page 15: ...ferrite toroids Nautel Part LP23 85 7 mm from the installation kit Install the ferrite toroid s on the VS2 5 end of the RF feed line If practical the RF feed line should pass through a minimum of two...

Page 16: ...e 4 2 Issue 11 0 2019 05 10 Figure 4 1 Routing RF Feed Line Through Ferrite Toroid 4 Install the appropriate size connector 7 8 inch EIA or 7 16 DIN on the RF feed line 5 Mate the RF feed line s conne...

Page 17: ...nnected to the safety ground stud at the rear of the VS2 5 see Figure 5 1 on page 5 2 6 If desired install the ac entrance box Nautel Part 211 5120 01 provided in the transmitter s installation kit on...

Page 18: ...conductor 9 Connect the ac power source by inserting each wire into its respective terminal block noting the following connections for each wire LINE 1 wire to TB1 1 LINE 2 NEUTRAL wire to TB2 1 AC GN...

Page 19: ...eft hand side of the transmitter as viewed from the front see Figure 5 3 on page 5 4 Discard hardware 6 Obtain the ac entrance box Nautel Part 211 5120 01 from the installation kit Position the ac ent...

Page 20: ...2019 05 10 Figure 5 2 Location of rear panel hardware to remove for ac entrance installation Figure 5 3 Location of rear panel hardware to remove for ac entrance installation Upper right hand rear se...

Page 21: ...VS2 5 Installation Manual Connecting ac power Issue 11 0 2019 05 10 Page 5 5 Figure 5 4 Partial rear views showing ac entrance box with strain relief cover on top...

Page 22: ...VS2 5 Installation Manual Connecting ac power Page 5 6 Issue 11 0 2019 05 10...

Page 23: ...errite toroid then to the rear of the VS2 5 If practical pass the cable through the ferrite toroid twice two turns 3 Connect the appropriate program input cable s between the program source s and the...

Page 24: ...lling program inputs Page 6 2 Issue 11 0 2019 05 10 Figure 6 1 Program Input Connections VS2 5 TRANSMITTER REAR VIEW NOTE D Sub mating connectors are provided in the ancillary kit Other connector type...

Page 25: ...the ferrite toroid a minimum of two times two turns 3 Connect the appropriate control monitor cable s to the connector s described in the Remote inputs Remote outputs or Analog outputs section of the...

Page 26: ...stalling control and monitoring wiring Page 7 2 Issue 11 0 2019 05 10 Figure 7 1 Control and Monitoring Connections VS2 5 TRANSMITTER REAR VIEW DIGITAL INPUTS AND INTERLOCK ANALOG AND DIGITAL OUTPUTS...

Page 27: ...e D sub connector that mates with REMOTE I O A A1J2A see Figure 7 1 To facilitate customer connections Nautel provides a mating plug Nautel Part JS28 in the ancillary kit for the REMOTE I O A A1J2A D...

Page 28: ...VS2 5 Installation Manual Installing control and monitoring wiring Page 7 4 Issue 11 0 2019 05 10...

Page 29: ...manufacturing Do not change any adjustments other than those specified This section contains the following procedures Pre Commissioning see page 8 2 Commissioning see page 8 3 Turning on the transmitt...

Page 30: ...ternal interlock pins 19 and 20 of the REMOTE I O A A1J2A connector on the rear of the VS2 5 safety features controlled by the external interlocks will be disabled A fail safe method of alerting perso...

Page 31: ...igure 8 1 to perform the first time setup of the VS2 5 including selecting the frequency output power and audio source Figure 8 1 First Time Setup Initial Screen SET FREQUENCY Press up down arrows to...

Page 32: ...options AES MPX over AES and Audio Player Use the up and down arrows to toggle between source options then press the checkmark button to select the desired source Continue to the next associated audi...

Page 33: ...splayed on line 2 of the top level screen should change to RF ON The VS2 5 should be operating at the preset parameters defined for preset 1 P1 6 Check the four LEDs on the left hand side of the front...

Page 34: ...Operation and Maintenance Manual WARNING If a jumper is placed between external interlock pins 19 and 20 of the REMOTE I O A A1J2A connector on the rear of the VS2 5 safety features controlled by the...

Page 35: ...VS2 5 4 If your network has a DHCP server and DHCP is set to ON factory default IP addresses will be automatically assigned Verify this has occurred by viewing the IP Address and Netmask address sub...

Page 36: ...way and nameservers Set to OFF if you do not have a DHCP server or if you wish to assign static addresses All addresses shown are for reference purposes only Specify a nameserver or DNS to enable the...

Page 37: ...Linux users can use ssh from the command line Change the OS password as follows 1 Connect to the transmitter IP address using your selected SSH client 2 Login with username root and the OS Password re...

Page 38: ...VS2 5 Installation Manual Commissioning Page 8 10 Issue 11 0 2019 05 10...

Page 39: ...ed by Nautel see page 9 2 Parts not supplied by Nautel see page 9 2 Parts ordering see page 9 2 Module replacement program see page 9 3 Tools for installation see page 9 3 Contacting Nautel You can re...

Page 40: ...tools Documentation See VS2 5 transmitter manuals on page xii Parts not supplied by Nautel Some parts and materials required to complete installation are not supplied by Nautel The parts you need var...

Page 41: ...modules with refurbished modules The replacement module is shipped to the customer as soon as the customer reports the failure The customer then returns the failed module to Nautel using the same ship...

Page 42: ...VS2 5 Installation Manual Parts and tools Page 9 4 Issue 11 0 2019 05 10...

Page 43: ...k with you to ensure that your site will be ready for the installation of your VS2 5 transmitter For support contact Nautel Customer Service and request assistance On site support on page 10 3 Install...

Page 44: ...on against lightning and lightning induced transients has been provided The transmitter has been unpacked closely checked for any damage caused by shipping and then assembled The following test equipm...

Page 45: ...binders that are delivered with the transmitter On site support If you require on site assistance Nautel s field support specialists can help you prepare your site and ensure that your VS2 5 transmit...

Page 46: ...ams are made up of individual modules that can be mixed and matched to meet the customer s specific training needs All Nautel training courses are available at the Nautel Training Center Training can...

Page 47: ...nt is operated within the design parameters and b when the equipment is installed and adjusted according to Nautel s prescribed procedures as stated in the instruction manual 3 Nautel shall provide re...

Page 48: ...s prior written approval 8 Nautel does not warrant that software a is free or errors bugs or defects b will be compatible with third party software c results output or data provided through or generat...

Page 49: ...Toll Free 1 877 6NAUTEL 6628835 Canada USA only Fax 1 902 823 3183 Nautel Inc 201 Target Industrial Circle Bangor Maine USA 04401 Phone 1 207 947 8200 Fax 1 207 947 3693 Customer Service 24 hour supp...

Page 50: ...performed by Nautel authorized personnel to repair the product back to factory specifications Necessary components Modifications to correct performance problems Return shipping Details Extended Warra...

Page 51: ...oll free number North America only to call for any service related issues Using the Extended Warranty Plan Contact Nautel s Canadian or U S service facility by phone fax or email as soon as a problem...

Page 52: ...VS2 5 Installation Manual Pre installation Installation assistance Page 10 10 Issue 11 0 2019 05 10...

Page 53: ...utput power caused by the occurrence of multiple shutbacks within a pre defined period Cycling ac power Turning off disabling then turning on enabling the ac power source DHCP Dynamic Host Carrier Pro...

Page 54: ...or shutback events SPI Serial Peripheral Interface A synchronous serial data link standard that operates in full duplex mode Devices communicate in master slave mode where the master device initiates...

Page 55: ......

Page 56: ...NAUTEL 662 8835 Canada USA only or Phone 1 902 823 3900 or Fax 1 902 823 3183 Nautel Inc 201 Target Industrial Circle Bangor Maine USA 04401 Phone 1 207 947 8200 Fax 1 207 947 3693 Customer Service 24...