NX5/NX3 INSTALLATION MANUAL
COMMISSIONING TASKS
VERSION 3.1 2021-04-22
PAGE 2.8.3
4.
Check the ac sample voltage using the local front panel UI (
Main Menu-> View Status -> View
Meters -> Rack
). This sample represents the transformer’s secondary voltage. It should be
between 302 V and 326 V. If so, proceed to
. If not, change the transformer tap setting as
follows:
If the ac sample voltage is too high, you will need to increase the tap voltage. If the ac sample
voltage is too low, you will need to decrease the tap voltage.
If the ac sample voltage is more than 4 V outside of the acceptable range (i.e., less than 298 V
or greater than 330 V), a “major tap change” is required. If the ac sample voltage is within
4 V of the acceptable range (i.e., between 298 and 302 V or between 326 and 330 V), a
“minor tap change” is required. See
for explanations of major and
minor tap changes.
Estimate the expected ac sample level for a major or minor tap change using the following
formula:
NOTE
: * denotes change only the major tap value or the minor tap value, as applicable.
Example # 1: If the ac sample voltage in
is 335 V, you require a “major” tap
increase. If the transformer is currently tapped at 380 V (360 - 505 V ac transformer), the
next higher major tap is 400 V (see
). Using the equation above
(noting “New Minor Tap” = 0), the “Ac Sample (new)” value is 318.2 V, which is within the
acceptable range.
Example # 2: If the ac sample voltage in
is 300 V, you require a “minor” tap
decrease (-10 V for the 360 - 505 V ac transformer; -5 V for the 200 - 250 V ac
transformer). If the transformer is currently tapped at 380 V (360 - 505 V ac transformer),
use the equation above (noting “New Major Tap”= “Current Major Tap”; in this example
380 V), the “Ac Sample (new)” value is 308.1 V, which is within the acceptable range.
If the proposed tap change yields an expected Ac Sample between 302 V and 326 V, perform
the “major” or “minor” tap change, using
,
and
Section 2.4, “Connecting Ac Power”
as guides.
Ensure the ac sample voltage on the front panel UI is between 302 V and 326 V. If not, repeat
.
Ac Sample (new)
Ac Sample (Step 4)
Current Major Tap
New Major Tap* New Minor Tap*
+
-----------------------------------------------------------------------------------------
×
=
Summary of Contents for NX3
Page 2: ......
Page 4: ......
Page 8: ...NX5 NX3 INSTALLATION MANUAL PAGE 2 VIII VERSION 3 1 2021 04 22...
Page 32: ...NX5 NX3 INSTALLATION MANUAL ADJUSTING THE SPARK GAP PAGE 2 5 4 VERSION 3 1 2021 04 22...
Page 54: ...NX5 NX3 INSTALLATION MANUAL COMMISSIONING TASKS PAGE 2 8 12 VERSION 3 1 2021 04 22...
Page 58: ...NX5 NX3 INSTALLATION MANUAL PARTS AND TOOLS PAGE 2 9 4 VERSION 3 1 2021 04 22...
Page 69: ......