VX150 TO VX2 INSTALLATION MANUAL
COOLING REQUIREMENTS
PAGE 1.4.2
VERSION 0.3 2021-01-14
Cooling
Do not allow the transmitter room ambient air temperature to exceed 50°C (122°F) at sea level. Cooler
temperatures are recommended in order to improve the reliability of the transmitter. The transmitter
contains protection circuits that monitor the intake temperature and may inhibit or reduce the RF
output power if the temperature exceeds the acceptable limit. At higher altitudes, derate the maximum
intake air temperature as follows:
De-rate the ambient temperature 3ºC (5.4°F) per 500 m – or 2ºC (3.6°F) per 1,000 feet – above sea
level.
Example:
At 1600 m (1 mile or 5280 ft) above sea level, maximum ambient temperature should
not exceed 40.4ºC (104.7°F).
Ensure that hot, exhaust air from the transmitter is not drawn back into the transmitter’s cool air intake.
Cooling Plant Requirements
Table 1.4.1: Cooling Plant Requirements for the VX Transmitter
Calculating BTU Cooling Requirements
To determine the number of British thermal units (Btu) being generated per hour as waste heat, multiply
the waste heat (in watts), derived from the transmitter output power and its typical efficiency, by 3.413.
Heating
The transmitter room must contain a heating system that will ensure the ambient air temperature does
not drop below 0°C (32°F).
TRANSMITTER
(FM MODE)
OUTPUT
POWER
(WATTS)
TYPICAL
EFFICIENCY
(%)
WASTE
HEAT
(WATTS)
BTU/HOUR
TYPICAL AIR CONDITIONING
REQUIRED IN CLOSED ROOM
COOLING (TONNES)
VX150
165
51.3
80
273
0.023
VX300
330
64.6
117
399
0.033
VX600
660
73.7
174
594
0.049
VX1
1100
75.2
273
932
0.078
VX1.5
1650
72.5
454
1550
0.129
VX2
2200
74.9
552
1884
0.157
Summary of Contents for NARF79
Page 2: ......
Page 4: ......
Page 10: ...VX150 TO VX2 INSTALLATION MANUAL PAGE VIII VERSION 0 3 2021 01 14...
Page 14: ...VX150 TO VX2 INSTALLATION MANUAL PAGE XIV VERSION 0 3 2021 01 14...
Page 22: ...VX150 TO VX2 INSTALLATION MANUAL PAGE XXII VERSION 0 3 2021 01 14...
Page 26: ...VX150 TO VX2 INSTALLATION MANUAL DESCRIPTION PAGE 1 1 4 VERSION 0 3 2021 01 14...
Page 36: ...VX150 TO VX2 INSTALLATION MANUAL ELECTRICAL REQUIREMENTS PAGE 1 5 4 VERSION 0 3 2021 01 14...
Page 38: ...VX150 TO VX2 INSTALLATION MANUAL RF OUTPUT REQUIREMENTS PAGE 1 6 2 VERSION 0 3 2021 01 14...
Page 42: ...VX150 TO VX2 INSTALLATION MANUAL PROGRAM INPUTS PAGE 1 7 4 VERSION 0 3 2021 01 14...
Page 44: ......
Page 54: ...VX150 TO VX2 INSTALLATION MANUAL CONTROL AND MONITOR WIRING PAGE 1 8 10 VERSION 0 3 2021 01 14...
Page 74: ...VX150 TO VX2 INSTALLATION MANUAL PARTS AND TOOLS PAGE 1 12 4 VERSION 0 3 2021 01 14...
Page 84: ...VX LP INSTALLATION MANUAL LIST OF TERMS PAGE 1 14 2 VERSION 0 3 2021 01 14...
Page 85: ......