background image

Single Use Pre-

Sized XactTrace™ Belt System User Instructions 

Warnings and Cautions 

 

XactTrace shall be worn over the patient's clothing The belts are 
single use. 

 

Do not stretch the belts too tightly around the patient as this may 
cause discomfort 

 

Caution must be taken to ensure that cables do not encircle the 
patient's neck. Special attention is needed in the case of children. 

 

Use the device only under the direction and supervision of a 
physician or trained technologist. 

 

Avoid all unnecessary contact with moisture when using the device.  

 

Do not use damaged belts, sensors or cables. 

 

Caution: U.S. Federal law restricts this device to sale by, or on the 
order of, a physician. 

 

This product is for diagnostic purposes only, and is not to be used as 
an apnea monitor. 

 

Do not use the device in an explosive environment

—in other words, 

in the presence of flammable liquids, such as an anesthetic mixture 
with air, or with oxygen or nitrous oxide. 

 

Connect the XactTrace sensors only to an input that is electrically 
isolated from the mains power. Do not plug the cables into electrical 
outlets, as this could result in serious electrical shock. 

 

Portable and mobile RF communications can affect the performance 
of the device. 

 

Electrostatic discharges (ESD) may cause artifacts in the signal from 
the device. A trained operator should be able to recognize these 
artifacts easily. Avoid conditions where electrostatic charge can build 
up due to low humidity and friction against carpets, clothing, and 
sheets made from artificial fibers. 

 

Universal applications require an external RIP Processor which 
contains a battery; therefore, it must be disposed of properly. Local, 
state, or national laws might prohibit disposal of batteries in ordinary 
trash. Contact your local waste authority for information regarding 
available recycling and disposable options. 

Summary of Contents for XactTrace

Page 1: ...and attaching the belts storage and cleaning Intended Use XactTrace is intended to measure respiratory effort to assist in the diagnosis of sleep disorders or sleep related respiratory disorders The r...

Page 2: ...other words in the presence of flammable liquids such as an anesthetic mixture with air or with oxygen or nitrous oxide Connect the XactTrace sensors only to an input that is electrically isolated fr...

Page 3: ...an be purchased to interface the locks with most PSG systems that accept the 1 5mm female touchproof connectors Belt Sensor Fitting the XactTrace Belts The belts are intended to be worn over nightclot...

Page 4: ...gly without being uncomfortably tight Measure the patient s circumference and use the table below as a guideline The belts are single use XactTrace Belt Sizes Full Size Reduced Size cm Inches cm Inche...

Page 5: ...ector as shown in the figure below The belt should fit snugly without being uncomfortably tight 2 Prepare the abdomen belt in the same manner only this time fit the belt around the patients stomach an...

Page 6: ...sor module labels are color coded for easy identification and connection 5 Plug the thorax and the abdomen module outputs into the appropriate bipolar inputs on your polygraph The red touch proof plug...

Page 7: ...Fitting the XactTrace Belts Material Elastic belt W 25 WHITE TERYLENE WITH WIRE UL1571 28 WHITE Cable Length 16 inches 41 cm Thorax 26 inches 66 cm Abdomen or 78 inches 200 cm Thorax Abdomen Material...

Page 8: ...heric pressures from 7 3 psi to 29 psi Output Specifications RIP Processor Output Signal Maximum signal amplitude 2mV Frequency Range 0 2 to 3 Hz Sensitivity Approximately 50 V mm Storage Proper stora...

Page 9: ...fects in materials and workmanship for 6 months from the date purchased The sole liability of Embla and our distributors is limited to replacement or repair of the product at the option of Embla with...

Page 10: ...nditions of sale of Natus Neurology Incorporated or its distributors Natus Neurology Incorporated makes no representations or warranties of any kind whatsoever with respect to this document Natus Neur...