WilTec GmbH is not responsible for detrimental effects and damage caused by an excessively 
high outlet pressure of the booster pump on the water softener.

 

 

If the main water supply is interrupted, the main valve of the supply line should be closed im-
mediately or the bypass valve of the water softener should be switched to the bypass station to 
prevent  the  water  softener  from  being  damaged  by  the  negative  pressure  in  the  pipework 
caused by the municipal water supply.

 

 

When the main water supply is restored, a large number of pollutants in the water pipe contam-
inate the treatment device. Therefore, first switch the bypass valve of the treatment device to 
the bypass station, open the tap in the house, and drain the water from the dirty water supply 
station.

 

 

The water softener must not be tilted or laid on its side during transport, installation or use.

 

 

The  floor  on  which  the  water  treatment  device  is  installed  should  be  level  and  have  a  load-
bearing capacity of more than 300

 

kg

m

. In addition, an AC power supply, a water inlet and outlet 

interface, a waste water pipe, and a floor drain should be available.

 

 

Installation area:

 

o

 

SOFT-V1: 380 × 550 × 690

 

mm (L×W×H)

 

o

 

SOFT-V2: 380 × 550 × 1150

 

mm (L×W×H)

 

 

Do not install the softener near acidic and alkaline substances or near gases to avoid corrosion 
on the softener.

 

 

The water softener must be installed indoors. Measures must be taken to insulate the housing 
and pipework, in particular to protect against frost and solar radiation and for sealing.

 

 

It is forbidden to install the softener on a water pipe with a water pressure of more than 4.5

 

bar. 

If the water inlet pressure exceeds 4.5

 

bar, a pressure-reducing valve must be installed (to be 

purchased  separately),  otherwise  the  company  accepts  no  responsibility  for  consequences 
such as impairment or damage to the water softener due to excessive water inlet pressure and 
any resulting damage.

 

 

The water softener should be installed and used in a room with a floor drain and smooth drain-
age. If the drain pipe or floor drain is blocked and the drain pump cannot drain normally due to 
a power failure or other malfunction, please close the building’s main water inlet valve immedi-
ately. At the installation site, it must be ensured that objects in the neighbouring area or in the 
part of the building below are not damaged or flooded if water escapes from the water softener 
or the connection pipe.

 

 

As shown in the illustration below, the drain pipe and the overflow pipe must be secured with 
ring clamps to prevent leakage during water drainage.

 

 

 

Fig.

 

1

 

Fig.

 

2

 

 

 

Before connecting the water supply pipe, remove any dirt and dust remaining in the pipe. Then 
close the main valve before connecting the system.

 

 

The overflow and drain pipe must be provided with a free pipe guide. The length of the pipe may 
not be increased and the pipe diameter may not be reduced without authorisation.

 

 

For the pipe connection, the pipe should be as close to the wall as possible, the pipe should run 
straight, and the angles should be free. After installation, the pipe should be fixed to the wall 
with a ring clamp. Pay attention to the height and placement angle of the pipe when it is con-
nected.  There  should  be  no  obvious  stresses  after  connecting  the  pipe  to  avoid  water  pipe 
bursts and water leakage from the treatment device or pipework due to stresses in the pipework 
during long-term use.

 

 

It is forbidden to combine the overflow and drain pipes in one pipe and insert it into the waste-
water outlet.

 

Summary of Contents for SOFT-HB1B

Page 1: ...operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous furt...

Page 2: ...u have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recen...

Page 3: ...ter softener is only suitable for filtering pre treated tap water It cannot be used to filter water with an unknown level of contamination or an unknown proportion of harmful organisms The water softe...

Page 4: ...d During operation of the water softener shocks to the water must be avoided e g by quickly opening or closing the valve and switching off the water pump in emergencies Do not apply force to the machi...

Page 5: ...u Item 63922 63923 Page 5 11 2023 1 Overview Name Name 1 Inlet outlet 7 Belt 2 Relief valve 8 Overflow fitting 3 LCD display 9 Brine tank and valve 4 Control panel 10 Housing 5 Top cover 11 FRP tank 6...

Page 6: ...resin capacity raw water hardness and regeneration coefficient This happens when the remaining amount of water produced drops to zero and the regeneration trigger time has been reached the factory set...

Page 7: ...water in the brine tank is topped up from the bottom and the salt water settles from the top to the bottom so that the salt water is mixed evenly by natural circulation and the saturated state can be...

Page 8: ...et pressure exceeds 4 5 bar a pressure reducing valve must be installed to be purchased separately otherwise the company accepts no responsibility for consequences such as impairment or damage to the...

Page 9: ...rflow pipe must not be connected to the sewage system in a sealed manner as otherwise the machine can no longer work normally or the waste water can no longer flow back to the machine due to the negat...

Page 10: ...pipe as required and lay them accordingly secure the hoses with clamps arrange the drain pipe and overflow pipe and connect them to the floor drain Name Name 1 Connecting table of control panel 8 Drai...

Page 11: ...inlet and outlet direction Then insert the large insert from the accessory kit into the slot of the bypass valve and the water pipe connection Then connect the display connection cable of the control...

Page 12: ...s valve water pipe Name Name 1 Inlet pipe 3 Overflow 2 Outlet pipe 4 Drain pipe Name Name 1 O ring 3 Outlet 2 Intake Note Make sure that the large clip on the bypass valve is inserted all the way to t...

Page 13: ...supply service mode Fig 3 If the bypass is in bypass mode Fig 4 pull the push rod into the water supply position Fig 3 Water supply mode Bypass mode Fig 1 Fig 2 Name description Name 1 Bar 3 Flow mete...

Page 14: ...ortion of mixed water and the higher the de gree of hardness of the outgoing water If the water mixing function is not required the water mixing plug can be installed Name Name 1 With water mixing fea...

Page 15: ...outlet points must not be installed in reverse Connect the water inlet and outlet pipes the drain pipes and the overflow pipes in sequence to ensure that all connections are tight and that there are n...

Page 16: ...opened Attention If the water inlet valve is fully opened directly the water will flow into the softener too quickly causing the softener resin in the tank to be stirred up which will easily cause th...

Page 17: ...r softener must stand for 6 hours so that the salt particles filled into the brine tank can dissolve sufficiently and a sufficiently concentrated brine is produced In the unlocked state press to start...

Page 18: ...ed regularly the actual product may differ from the instructions Note As the pressure in the water pipe fluctuates the water pressure is generally higher at night than during the day it is advisable t...

Page 19: ...alve to end the current operating status prematurely and move on to the next operating position If for example the hardness of the outlet water is unsuitable press the button after unlocking to stop t...

Page 20: ...hanged Regeneration time All 2 00 00 00 23 59 Maximum regenera tion days All 30 0 99 If the set time has elapsed and the re maining water produc tion has not reached the set value the regenera tion pr...

Page 21: ...layed as shown in Fig F During a quick rinse the menu is displayed as shown in Fig G When the valve rotates from one operating position to another the menu is displayed as shown in Fig H If there is a...

Page 22: ...e control valve This means that different operating modes have different setting menus The description of the setting lines of the unla belled operating modes is displayed in all operating modes Opera...

Page 23: ...n no longer be excreted after heating there fore also referred to as permanent hardness Testing the raw water hardness Immerse the reaction zone of the hardness test paper in the liquid to be tested f...

Page 24: ...down button to set the number of hours 3 Press the button again the minutes 00 flash Press the up or down button to set the number of minutes 4 Press again to save the modification of the regeneration...

Page 25: ...gh 1 Poor raw water quality 1 Contact a specialist 2 Too long a regeneration time 2 Re initialise regeneration time 3 Leakage of the water mixing valve or excessive opening of water mixing valve 3 Clo...

Page 26: ...igh or too low 1 Incorrect control valve used 1 Replace with correct control valve 2 Foreign objects influence con trol valve 2 Clean control valve Note The above solutions are for reference only If t...

Page 27: ...nd other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domes...