Introduction

 

 

Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it.

 

Keep these operation instructions in a safe place.

 

 
 

Use and warning notices

 

 

 

Prohibition symbol

 

Any use described with this symbol is prohibited, as otherwise the prod-
uct could be damaged, the safety of users could be jeopardised, or ma-
terial damage could be caused.

 

 

Warning symbol

 

Any use described with this symbol must be carried out in strict compli-
ance with the regulations, otherwise the product could be damaged or 
the safety of the user could be jeopardised.

 

 

Instruction symbol

 

All instructions marked with this symbol must be observed by the user, 
otherwise  the  product  may  be  damaged  or  other  damage  may  occur 
due to improper operation.

 

 

 

Installation, commissioning, or maintenance of this water softener must be carried out by qual-
ified personnel.

 

 

Liability for consequences caused by improper installation is excluded.

 

 
 

Safety instructions

 

 

 

The water softener can only be supplied with 12

 

V and 1500 mA. Observe all safety precautions 

in connection with the operation of electrical appliances during operation and maintenance.

 

 

If the mains cable of the water softener is damaged, it must be repaired by a qualified electrician.

 

 

The water softener is only suitable for filtering pre-treated tap water. It cannot be used to filter 
water with an unknown level of contamination or an unknown proportion of harmful organisms.

 

 

The water softening liquid cannot be drunk directly. Do not drink it directly.

 

 

Do not block the overflow pipe and the drain pipe of the water softener.

 

 

Do not place any objects on the water softener.

 

 

Do not immerse the water softener in water.

 

 

Do not use the water softener outdoors or in direct sunlight.

 

 

The temperature of the water entering the treatment device must not exceed 38

.

 

 

After the water softener has been out of operation for a certain period of time, manual treatment 
must be carried out before reuse to ensure the quality of the water produced.

 

 

The power supply must not be interrupted while the water softener is in use in order to avoid 
timing errors of the water softener, which would affect the originally set regeneration start time 
of the water softener. Otherwise, users could misuse water that has not yet been softened.

 

 

If the water consumption increases significantly (compared to normal consumption) or the hard-
ness of the raw water increases, the regeneration cycle must be shortened accordingly or the 
hardness of the raw water must be adjusted so that the regeneration times are extended.

 

 

As hot water can severely damage the internal treatment system, it should be ensured that there 
is a connecting pipe of at least 3

 

m in length between the outlet of the softener and the inlet of 

the hot water boiler. If the 3-m connection line cannot be assured, it is recommended to install 
a non-return valve between the water softener and the hot water boiler.

 

Summary of Contents for SOFT-HB1B

Page 1: ...operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous furt...

Page 2: ...u have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recen...

Page 3: ...ter softener is only suitable for filtering pre treated tap water It cannot be used to filter water with an unknown level of contamination or an unknown proportion of harmful organisms The water softe...

Page 4: ...d During operation of the water softener shocks to the water must be avoided e g by quickly opening or closing the valve and switching off the water pump in emergencies Do not apply force to the machi...

Page 5: ...u Item 63922 63923 Page 5 11 2023 1 Overview Name Name 1 Inlet outlet 7 Belt 2 Relief valve 8 Overflow fitting 3 LCD display 9 Brine tank and valve 4 Control panel 10 Housing 5 Top cover 11 FRP tank 6...

Page 6: ...resin capacity raw water hardness and regeneration coefficient This happens when the remaining amount of water produced drops to zero and the regeneration trigger time has been reached the factory set...

Page 7: ...water in the brine tank is topped up from the bottom and the salt water settles from the top to the bottom so that the salt water is mixed evenly by natural circulation and the saturated state can be...

Page 8: ...et pressure exceeds 4 5 bar a pressure reducing valve must be installed to be purchased separately otherwise the company accepts no responsibility for consequences such as impairment or damage to the...

Page 9: ...rflow pipe must not be connected to the sewage system in a sealed manner as otherwise the machine can no longer work normally or the waste water can no longer flow back to the machine due to the negat...

Page 10: ...pipe as required and lay them accordingly secure the hoses with clamps arrange the drain pipe and overflow pipe and connect them to the floor drain Name Name 1 Connecting table of control panel 8 Drai...

Page 11: ...inlet and outlet direction Then insert the large insert from the accessory kit into the slot of the bypass valve and the water pipe connection Then connect the display connection cable of the control...

Page 12: ...s valve water pipe Name Name 1 Inlet pipe 3 Overflow 2 Outlet pipe 4 Drain pipe Name Name 1 O ring 3 Outlet 2 Intake Note Make sure that the large clip on the bypass valve is inserted all the way to t...

Page 13: ...supply service mode Fig 3 If the bypass is in bypass mode Fig 4 pull the push rod into the water supply position Fig 3 Water supply mode Bypass mode Fig 1 Fig 2 Name description Name 1 Bar 3 Flow mete...

Page 14: ...ortion of mixed water and the higher the de gree of hardness of the outgoing water If the water mixing function is not required the water mixing plug can be installed Name Name 1 With water mixing fea...

Page 15: ...outlet points must not be installed in reverse Connect the water inlet and outlet pipes the drain pipes and the overflow pipes in sequence to ensure that all connections are tight and that there are n...

Page 16: ...opened Attention If the water inlet valve is fully opened directly the water will flow into the softener too quickly causing the softener resin in the tank to be stirred up which will easily cause th...

Page 17: ...r softener must stand for 6 hours so that the salt particles filled into the brine tank can dissolve sufficiently and a sufficiently concentrated brine is produced In the unlocked state press to start...

Page 18: ...ed regularly the actual product may differ from the instructions Note As the pressure in the water pipe fluctuates the water pressure is generally higher at night than during the day it is advisable t...

Page 19: ...alve to end the current operating status prematurely and move on to the next operating position If for example the hardness of the outlet water is unsuitable press the button after unlocking to stop t...

Page 20: ...hanged Regeneration time All 2 00 00 00 23 59 Maximum regenera tion days All 30 0 99 If the set time has elapsed and the re maining water produc tion has not reached the set value the regenera tion pr...

Page 21: ...layed as shown in Fig F During a quick rinse the menu is displayed as shown in Fig G When the valve rotates from one operating position to another the menu is displayed as shown in Fig H If there is a...

Page 22: ...e control valve This means that different operating modes have different setting menus The description of the setting lines of the unla belled operating modes is displayed in all operating modes Opera...

Page 23: ...n no longer be excreted after heating there fore also referred to as permanent hardness Testing the raw water hardness Immerse the reaction zone of the hardness test paper in the liquid to be tested f...

Page 24: ...down button to set the number of hours 3 Press the button again the minutes 00 flash Press the up or down button to set the number of minutes 4 Press again to save the modification of the regeneration...

Page 25: ...gh 1 Poor raw water quality 1 Contact a specialist 2 Too long a regeneration time 2 Re initialise regeneration time 3 Leakage of the water mixing valve or excessive opening of water mixing valve 3 Clo...

Page 26: ...igh or too low 1 Incorrect control valve used 1 Replace with correct control valve 2 Foreign objects influence con trol valve 2 Clean control valve Note The above solutions are for reference only If t...

Page 27: ...nd other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domes...

Reviews: