Electronic pellet burner controller – NPBC-V3C-1/ NPBC-V4C-1/ NPBC-V4E-1
(Optional)
Analog output for frequency inverter to power up a powerful air fan
Photo sensor to detect the burning fire
Temperature sensor or thermostat to control the back burning
Temperature sensor to control the temperature of the water in the boiler
Temperature sensor for the hot water heater
High temperature pt100 sensor to measure the temperature of the flue gases.
This temperature
sensor does not detect the burning fire, but only provides information
A potential free contact of a room thermostat for better control of the burning process
according to the room temperature.
USB interface for connection with a computer
NPBC-V3C
- 1/ NPBC-V4C
- 1
INPUTS
AND
OUTPUTS
DESCRIPTION
Outputs
Inputs
FM
Main fan
RT
Room thermostat. To this input could be
connected a normally opened or
normally closed contact, with no
additional voltage.
FSG
Fan for the flue gases
PS
Photo sensor
SF
Screw for fuel
RB
Reverse burning sensor
SB
Internal screw
B
Boiler temperature sensor
PH
Heating installation pump
WH
Water heater temperature sensor
PWH
Hot water heater pump
PT
pt100 high temperature sensor
IGN
Ignition heater
OD
Opened door switch
(Optional)
FC
Fan for cleaning
LED
ACF
Analog controlled fan
(Optional)
User Manual / ver 3.11
http://www.naturela-bg.com/en/
page 5 of 37