background image

8

 

 

Microcontroller digital accuracy   

 

Type of Charging       

 

 

      Series PWM  

          Temperature compensa on charging 

 

Electronic protec ons       

 

  Short circuit and over current- load 

                                                        Reverse polarity- ba ery 

                                                        Reverse current at night 

                                                        Limits high voltage to protect loads 

                                                        Lightning protec on 

 

Tropicaliza on                      Conformal coated printed circuit board 

 

Terminals                              For wire sizes to 2.5mm

²

 

 

Weights                             170g 

 

Dimension                          140*89mm 

 

Self-consump on             

 

6mA maximum 

 

Temperature                      -35 to +55  

 

Enclosure                            IP30 

 

Warranty                              1 year 

 

Compliance                        CE, EMC  C-Tick

 

 
 
 

Summary of Contents for 55701

Page 1: ...tem 55702 Thank you very much for choosing a Nature Power Product For future reference please complete the owner s record below Model _______________ Purchase Date _______________ iar with this produc...

Page 2: ...tions discussed in this instruction manual cannot cover all possible conditions or situations that could occur It must be understood by the operator that common sense and caution are factors which can...

Page 3: ...to Solar Panel port of Charge Controller 2 A ch the quick connect end of b ery clamps into Output port of Charge Controller 3 Connect the RED Posi ve clamp wire to the Posi ve b ery terminal 4 Connect...

Page 4: ...from the solar panel or via the Charge Controller are always Female Positive Polarity In case you need to have a Female Negative Polarity output you may use the Reverse Polarity Adapter provided CAUTI...

Page 5: ...s only Use with sealed ba eries only Do not exceed Solar and Load ra ngs 10A Note carefully check before making each connection to be certain the polarity is correct 5 Nature Power Model MAX10A 10 AMP...

Page 6: ...e controller will have 4 automa c loads reconnect a empts There will be 10s between the rst three a empts and 20s between the 3 rd and 4 th a empts For the h short circuit the load can be only reconne...

Page 7: ...r switch Please note the ba ery voltage needs to be over 12 5V To correct problem 1 Check wires 2 Reduce amps if needed 3 Reset controller Disconnect ba ery Reconnect ba ery TECHNICAL INFORMATION Equa...

Page 8: ...urrent load Reverse polarity ba ery Reverse current at night Limits high voltage to protect loads Lightning protec on Tropicaliza on Conformal coated printed circuit board Terminals For wire sizes to...

Page 9: ...9 SYSTEM MAIN CIRCUIT DIAGRAM MECHANICAL DRAWING...

Page 10: ...ould be returned a Return Authoriza on Number must be issued by Nature Power and th or unit should be returned to the authorized loca on at the purchasers expense A dated proof of purchase is required...

Reviews: