7
2. A er over discharged, the load will be reconnected automa cally when
the ba ery is charged to 13.1V.
A er over discharged, the load will be reconnected while you press the
power switch. Please note the ba ery voltage needs to be over 12.5V.
To correct problem
1.
Check wires
2.
Reduce amps if needed
3.
Reset controller
Disconnect ba ery +
Reconnect ba ery
+
TECHNICAL INFORMATION
Equaliza on voltage (60 minutes)
14.8 V
Boost voltage (60 minutes)
14.4 V
Float Voltage 13.7V
Low voltage Disconnect
11.1 V
Low voltage Reconnect 13.1 V
Note: all is for 12V system only