Troubleshooting Guide
NCC7222-07 R2- 111207
19
Cause
Action
1. Filter not completely rotated into correct position.
1. Some filters (produced June 2007) have been spinwelded
incorrectly and can only be rotated clockwise into ION to a
certain point. If you want these filters replaced, contact the factory.
2. Ice Bank leak
2. Level inside Ice Bank is checked by software every 24 hours and
refilled (2 minute limit)… a small pinhole leak inside Ice Bank can
cause leak. Contact factory for replacement.
3. Tubing, Fitting, or Valve Leak
3. Check all fittings, tubing, and valves, and repair as needed.
Problem: Water Leak
IMPORTANT – the ION uses an Inlet Valve to allow water to enter the appliance. Only when the customer presses
Touch Panel to dispense water – or when Ice Bank automatically fills – does the Inlet Valve open to allow water to enter
the appliance.
On units with “Bypass” feature, the Inlet Valve is bypassed to allow for Filter Water from the ION to be routed out the
back of the appliance and over to a coffee machine. This option provide for continuous water flow (bypassing the Inlet
Valve) and is not recommended for installations that want to maintain the maximum level of leak prevention.
Summary of Contents for ION pure refreshment
Page 1: ...NCC7222 07 R2 111207 TECHNICAL SERVICE MANUAL...
Page 22: ...Frame Assembly NCC7222 07 R2 111207 21...
Page 23: ...Display Valve Assembly Models 903 904 only NCC7222 07 R2 111207 22 for Models 903 904 only...
Page 24: ...NCC7222 07 R2 111207 Filter Manifold Assembly 23...
Page 25: ...Front Panel Assembly NCC7222 07 R2 111207 24...
Page 26: ...Dispensing Assembly 901 NCC7222 07 R2 111207 25...
Page 27: ...Dispensing Assembly 902 NCC7222 07 R2 111207 26...
Page 28: ...Dispensing Assembly 903 NCC7222 07 R2 111207 27...
Page 29: ...Dispensing Assembly 904 NCC7222 07 R2 111207 28...