Problem: No Water Dispenses From Cold or Sparkling Valve
IMPORTANT – Do you hear both Inlet Valve and Cold Valve “double-click” when opening and closing?
Inlet Valve must open to allow water into ION. Dispensing Valve then allows water out of appliance.
Therefore, when dispensing water, you will hear two valves clicking open and closed in quick
succession. The clicking indicates the plunger is moving up and down and that the valve has electrical
current. Place your finger on the back of the appliance where Inlet Valve is located and you can feel it
click open and closed. Place your finger on Dispensing valve and you can also hear it click open and
closed. A dead valve (no electrical current) is indicated when you cannot feel the plunger moving
up inside.
Troubleshooting Guide
NCC7222-07 R2- 111207
12
Cause
Action
1. Dead Valve - No electrical current.
1. Check Touch Panel connector to Display Board,
behind Front Panel.
Check valve wiring on Control Board.
Check DIP Switch setting for correct ION model
(see wiring diagram).
2. Valves are clicking, indicating electrical current is present.
2. Double-check Water Supply tubing, shutoff valves, and undersink
connection.
Check inside Ice Bank for frozen Ice Bank … thaw and set
DIP 4 to UP position. Or contact factory for latest software
revision level.
Summary of Contents for ION pure refreshment
Page 1: ...NCC7222 07 R2 111207 TECHNICAL SERVICE MANUAL...
Page 22: ...Frame Assembly NCC7222 07 R2 111207 21...
Page 23: ...Display Valve Assembly Models 903 904 only NCC7222 07 R2 111207 22 for Models 903 904 only...
Page 24: ...NCC7222 07 R2 111207 Filter Manifold Assembly 23...
Page 25: ...Front Panel Assembly NCC7222 07 R2 111207 24...
Page 26: ...Dispensing Assembly 901 NCC7222 07 R2 111207 25...
Page 27: ...Dispensing Assembly 902 NCC7222 07 R2 111207 26...
Page 28: ...Dispensing Assembly 903 NCC7222 07 R2 111207 27...
Page 29: ...Dispensing Assembly 904 NCC7222 07 R2 111207 28...