background image

W

H

IT

E

TOUCH PANEL

-PIN CONNECTOR

BL

A

C

K

HOT TANK

TEMP SENSOR (TM3)

PART # 1785

DISPLAY  BOARD

 RIBBON CABLE

6

LEDS (2)

6

-CONDUCTOR

FILTER RESET SWITCH

HIGH 

VOLTAGE

AREA

SEE DATA PLATE FOR
INPUT SPECFICATION

GROUND

L1

24 VDC OUT

AC LINE 
VOLTAGE IN

PIN 4 = RED

PIN 1 = BLACK

(YELLOW)

OVERLOAD

24 VDC OUT

(BLUE)

PTC RELAY

POWER SUPPLY

24 VDC IN (J1)

DIP SWITCH

DIP SWITCH

PHOTO SENSOR

BLUE FAUCET LED

100-240 VAC IN

ICE BANK          

TEMP SENSOR (TM1)

GROUND

GROUND

SCREW

SCREW

10-CONDUCTOR

 RIBBON CABLE

TO J21

ICE BANK          

LEVEL SENSOR (TM5)

ELECTRICAL SCHEMATIC

Natural Choice Corporation

Rockford, IL 61109 phone 815.874.4444     www.naturalchoicewater.com       All Rights Reserved, Natural Choice Corp.

OPTIONAL INPUT

(UNUSED)

PIN 3 = RED

PIN 1 = WHITE

TO UNIT BEFORE SERVICE.

DANGER-RISK OF DEATH

WARNING-HIGH VOLTAGE ON 

ALWAYS UNPLUG POWER SUPPLY

MAIN CONTROL BOARD. 

OPTIONAL INPUT

(UNUSED)

INLET

VALVE
#6518

ICE BANK 

FILL VALVE

#6519

PIN 3   - WHITE
PIN 2  + RED
PIN 1     

PIN 3   - BLACK
PIN 2  
PIN 1   + RED

COMPRESSOR

FAN

HEATER

H2O

REF

COMP

ICE BANK PUMP

RELAY (K3)

FUSE - ICE BANK

PUMP (0.5 AMP)

PIN 3   - WHITE
PIN 2     
PIN 1   + RED

PIN 3   
PIN 2   - WHITE
PIN 1  + RED

PIN 3   
PIN 2   - WHITE
PIN 1  + RED

PIN 3   
PIN 2   - WHITE
PIN 1  + RED

ICE

BANK

PUMP

PIN 3 = BLACK

PIN 2 = WHITE

POWER INLET

IEC SOCKET

GROUND

GROUND

SCREW

SCREW

NEUTRAL

Model Valves

Touch Panel

Location

DIP Setting

901 

Cold #6516                      C 

 

 

Ambient #6516              D 

 

D

902 

Cold #6516                      C 

 

C

 

Hot #6517                        D 

 

D

903 

Cold #6516                      C 

 

 

 

Sparkling #6516             D 

 

D

904 

Cold #6516                      C 

 

 

 

Hot #6517                        D 

 

D

 

Sparkling #6516             B 

 

B

905 

Cold #6516                      C 

 

 

Hot #6517                        D 

 

D

 

Ambient #6516              B 

 

 

Circuit Board

Location

B

C

D

PIN 3   
PIN 2   - WHITE
PIN 1  + RED

HOT #6517

COLD #6516

SPARKLING/AMBIENT #6516

A

D

C

B

DIP chart reference - 0 is DOWN and 1 is UP

DIP positions 4, 5, and 6 are special function

contact factory for more information

DIP positions 1, 2, and 3 control model setting

PART # 1784

CONTROL  BOARD

0 0 1 0 0 0

1 1 0 0 0 0

1 0 1 0 0 0

0 1 0 0 0 0

1 0 0 0 0 0

SPARKLING/AMBIENT #6516

24 Volt DC 
Components

24 Volt DC 
Components

(rev1 - for models produced 

after 

April 15)

NCC7222-07 R2- 111207

Wiring Diagram

9

Summary of Contents for ION pure refreshment

Page 1: ...NCC7222 07 R2 111207 TECHNICAL SERVICE MANUAL...

Page 2: ...ed Squeeze sides at arrows and lift Loosen 2 screws at top rear Pull panel up at rear Then roll to right front corner Remove 3 screws left side Slide back 1 inch Tilt panel down to remove Remove Fauce...

Page 3: ...2 07 R2 111207 Control Board Front Panel Assembly Filter Access Compressor Hot Tank LED SleepMode Sensor Touch Panel Faucet Power Supply Ice Bank Major Components Service View 2 LED1 LED2 Sleep Mode S...

Page 4: ...oil Ice Bank Pump is activated for 1 minute every time Cold or Sparkling water is dispensed Ice Bank Pump comes on automatically for 1 minute every 10 minutes Level Sensor at front of Ice Bank automat...

Page 5: ...Ice Bank from Fill Valve Inlet to Ice Bank from Filter Stainless Steel Water Coil Alternate Location for Cold Thermistor Cold Thermistor Evaporator Level Sensor Ice Bank Pump Tee to Hot or Ambient Wat...

Page 6: ...InstaChill Cooling System NCC7222 07 R2 111207 5 Model 904 Cold Hot and Sparkling Model 905 Cold Hot and Ambient Model 903 Cold and Sparkling...

Page 7: ...Ice Bank water is directed to Dispensing Valves at the outlet of the appliance for Cold Ambient Sparkling and Hot Water KEY LEARNING when you press one of the icons on the Touch Panel you are opening...

Page 8: ...ank by removing 1 4 plug at bottom of Hot Tank elbow fitting MANUAL FILL On first STARTUP only the software will force you to make sure the Hot Tank is filled On every subsequent STARTUP make sure the...

Page 9: ...pMode default is ON F May 31 2007 Changed Level Sensor setting G not implemented H June 6 2007 Corrected Filter Reset button to change LED s green Filter Monitor Settings default OFF J June 25 2007 Co...

Page 10: ...PIN 2 RED PIN 1 PIN 3 BLACK PIN 2 PIN 1 RED COMPRESSOR FAN HEATER H2O REF COMP ICE BANK PUMP RELAY K3 FUSE ICE BANK PUMP 0 5 AMP PIN 3 WHITE PIN 2 PIN 1 RED PIN 3 PIN 2 WHITE PIN 1 RED PIN 3 PIN 2 WHI...

Page 11: ...ater dispenses from Hot Valve page 14 Low or No Water Flow page 15 Blue LED not ON page 16 Blinking RED lights both together not alternating page 17 Steady Orange lights never goes to blinking Orange...

Page 12: ...ED ON or OFF 2 If Blue LED is OFF this indicates ION is in SleepMode To lockout ION from SleepMode see programming section in Owners Manual 3 ION may be plugged into outlet controlled by light switch...

Page 13: ...it click open and closed Place your finger on Dispensing valve and you can also hear it click open and closed A dead valve no electrical current is indicated when you cannot feel the plunger moving u...

Page 14: ...he hot tank connector and wiring harness at Control Board with ION unplugged and Switch in ON position 3 Thermal Overload in Hot Tank Assembly has been tripped from dry firing hot tank 3 Replace Therm...

Page 15: ...to Instruction Label inside filter door of appliance and notify customer 2 Do you hear both Inlet and Dispensing Valve clicking open and closed 2 Do you hear both Inlet and Dispensing Valve clicking...

Page 16: ...ter supply tubing 2 Check water supply tubing and cut cleanly with razor knife 3 Is copper tubing used at Inlet Valve 3 Do not use copper tubing to connect to ION appliance use a 1 4 compression union...

Page 17: ...nto the Control Board A photo sensor behind the LED3 on Front Panel allows software to turn the compressor OFF when room is dark Check the location carefully if room light is turned ON and OFF frequen...

Page 18: ...Normal Operation Problem Blinking RED lights both together not alternating IMPORTANT Ice Bank automatically fills by using a Level Sensor To prevent endless water flow from failed Level Sensor softwa...

Page 19: ...ors as needed If NO then replace Control Board programming error or defect on Control Board perhaps shipping damage is preventing Control Board from initialization Problem Steady Orange lights never g...

Page 20: ...3 Tubing Fitting or Valve Leak 3 Check all fittings tubing and valves and repair as needed Problem Water Leak IMPORTANT the ION uses an Inlet Valve to allow water to enter the appliance Only when the...

Page 21: ...y RED lights Filter Change required When pressing Filter Reset button does not reset RED lights to GREEN IMPORTANT When changing filters ALWAYS reset the filter monitor time and gallons to zero by pre...

Page 22: ...Frame Assembly NCC7222 07 R2 111207 21...

Page 23: ...Display Valve Assembly Models 903 904 only NCC7222 07 R2 111207 22 for Models 903 904 only...

Page 24: ...NCC7222 07 R2 111207 Filter Manifold Assembly 23...

Page 25: ...Front Panel Assembly NCC7222 07 R2 111207 24...

Page 26: ...Dispensing Assembly 901 NCC7222 07 R2 111207 25...

Page 27: ...Dispensing Assembly 902 NCC7222 07 R2 111207 26...

Page 28: ...Dispensing Assembly 903 NCC7222 07 R2 111207 27...

Page 29: ...Dispensing Assembly 904 NCC7222 07 R2 111207 28...

Page 30: ...Ice Bank Assembly NCC7222 07 R2 111207 29...

Page 31: ...Final Assembly NCC7222 07 R2 111207 30...