![background image](http://html1.mh-extra.com/html/national/nn-v680w/nn-v680w_service-manual_708371020.webp)
connector (CN6) from the DPC otherwise a false reading may
be indicated.
NOTE 2: If checking an oven sensor thermistor just after the
microwave oven has been operating, the sensor of course
won't be room temperature. In this case the sensor must be
removed and allowed to cool down to the 10°C to 30°C range.
20
NN-V690P / NN-V690PS / NN-V680W / NN-V680WS