background image

1.0 Introduction

In  the  Computer  mode  evaluation  is  simplified  by

connecting the board to the WaveVision Digital Interface

Board  (order  number  WAVEVSN  BRD  3.0),  which  is

connected  to  a  personal  computer  through  a  serial

communication  port  and  running  WaveVision  software,

operating  under  Microsoft  Windows.  Or  use  WAVEVSN

BRD 4.0 when available on National's web site. Use the

WaveVision2  program  (WAVEVSN2.EXE)  or  use

WaveVision 4.0 when available on National's web site.

These  Design  Kits  (each  consisting  of  an  Evaluation

Board, National's WaveVision software and this manual)

is designed to ease evaluation and design-in of Nationals

ADC12040,  ADC12010,  ADC12020,  or  ADC12L063  12-

bit  Analog-to-Digital  Converter,  which  operate  at  speeds

up  to  40  Msps,  10  Msps,  20  Msps  and  62  Msps,

respectively.  Further  reference  in  this  manual  to  the

ADC12040  is  meant  to  also  include  the  ADC12010,

ADC12020  and  the  ADC12L063,  unless  otherwise

specified or implied. Note that the maximum sample rate

capability of the  WaveVision  system  in  the  Computer  or

Automatic mode is 60 Msps.

The  signal  at  the  Analog  Input  to  the  board  is  digitized

and  is  available  at  pins  B16  through  B21  and  C16

through  C21  of  J2.  Pins  A16  through  A21  of  J2  are

ground pins.

The  WaveVision  software  can  be  operated  under

Microsoft  Windows.  The  signal  at  the  Analog  Input  is

digitized  and  can  be  captured  and  displayed  on  a  PC

monitor  as  a  dynamic  waveform.  The  digitized  output  is

also available at Euro connector J2.

Provision  is  made  for  adjustment  of  the  Reference

Voltage, VREF, with VR1.

2.0 Board Assembly

The  ADC12040  Evaluation  Board  may  come  pre-

assembled or as a bare board  that  must  be  assembled.

Refer  to  the  Bill  of  Materials  for  a  description  of

components, to 

Figure 1

 for major component placement

and to 

Figure 6

 for the Evaluation Board schematic.

The  software  can  perform  an  FFT  on  the  captured  data

upon  command  and,  in  addition  to  a  frequency  domain

plot,  shows  dynamic  performance  in  the  form  of  SNR,

SINAD, THD and SFDR.

A  breadboard  area  is  provided  for  building  customized

circuitry.  For  best  performance,  keep  circuitry  neat  and

arrange components to provide short, direct connections.

A  prototype  area  is  available  for  building  customized

circuitry.

The evaluation board can be used in either of two modes.

In the Manual mode suitable test equipment can be used

with the board to evaluate the ADC12040 performance.

+V
GND
+5V
-V

Y1

L3

T1

L4

L5

L2

L10

L1

RP2

RP1

U1

CLK SEL

JP2

VR1

-V

TP10

+V

TP8

   VDO

       TP2

TP20

OE-

TP7

ADC CLK

Vin+

TP3

Vin-

TP4

TP6

PWR DWN

POWER CONNECTOR

P1

TP5

SIG IN       

JP3

MIX

JP4

    SELECT

J3 

J1 

VREF

         TP1

+5V

TP9

D1

JS3

JS1

JS0

J1

Analog

Input

VR1

Ref. Adj.

TP1

V

REF

P1

Power

TP10

-V

JP2

CLK

SELECT

TP3

Vin+

TP8

+V

TP5

SIGNAL

INPUT

TP6

PWR

DWN

TP9

+5V

JP2

Detail

Default

Position

TP4

Vin-

J3

Analog

Input

JP3 & JP4

Detail

J1 Input

Position

TP7

ADC CLK

TP2

DR VD

JS3

Detail

Standard

JS0 & JS1

Detail

Standard

Figure 1.  Component and Test Point Locations

              

3

          

http://www.national.com

Summary of Contents for ADC12010

Page 1: ...040 12 Bit 40 Msps 5 Volt 380 mW A D Converter ADC12010 12 Bit 10 Msps 5 Volt 160 mW A D Converter ADC12020 12 Bit 20 Msps 5 Volt 185 mW A D Converter ADC12L063 12 Bit 62 Msps 3 3 Volt 354 mW A D Converter 2001 2002 2003 2004 National Semiconductor Corporation 1 http www national com ...

Page 2: ... circuit 5 4 5 Digital Data Output 6 4 5 Power Supply Connections 6 4 6 Power Requirements 6 5 0 Installing the ADC12040 Evaluation Board 6 6 0 Obtaining Best Results 6 6 1 Clock Jitter 6 6 2 Coherent Sampling 7 7 0 Evaluation Board Specifications 8 8 0 Hardware Schematic 9 9 0 Evaluation Board Bill of Materials 10 A1 0 Operating in the Computer Mode 12 A2 0 Summary Tables of Test Points and Conne...

Page 3: ...on a PC monitor as a dynamic waveform The digitized output is also available at Euro connector J2 Provision is made for adjustment of the Reference Voltage VREF with VR1 2 0 Board Assembly The ADC12040 Evaluation Board may come pre assembled or as a bare board that must be assembled Refer to the Bill of Materials for a description of components to Figure 1 for major component placement and to Figu...

Page 4: ...ics 4 To use the crystal oscillator located at Y1 to clock the ADC connect the jumper at JP2 to pins 2 and 3 This is the default position The ADC clock signal may be monitored at TP7 Because of clock isolation resistor R12 and the scope probe capacitance the clock signal at TP7 will appear integrated 5 Connect the jumper at JP3 between pins 1 and 2 and the jumper at JP4 to pins 1 and 2 to select i...

Page 5: ...e of 0 to 2 4 Volts for the ADC12040 ADC12010 and ADC12020 or 0 to 1 2 Volts for the ADC12L063 The ADC12040 ADC12010 and ADC12020 are specified to operate with VREF in the range of 1 0 to 2 4 V with a nominal value of 2 0V while the ADC12L063 is specified to operate with VREF in the range of 0 8 to 1 2 V with a nominal value of 1 0V The reference voltage can be monitored at test point TP1 and is s...

Page 6: ...rable plot of Figure 2b Note that all dynamic performance parameters shown to the right of the FFT are improved by eliminating clock jitter To develop the ADC clock WAVEVISON BRD 3 0 Digital Interface Board divides its on board clock to provide the ADC clock In doing so jitter is introduced to the ADC clock degrading the observed performance of the ADC The amount of jitter produced by this evaluat...

Page 7: ...umber of samples in the data record must be a factor of 2 integer We can eliminate the need for windowing and get more consistent results if we observe the proper ratios between the input and sampling frequencies We call this coherent sampling Coherent sampling greatly increases the spectral resolution of the FFT allowing us to more accurately evaluate the spectral response of the A D converter Wh...

Page 8: ...1 C21 A22 B22 C22 A23 B23 C23 A24 B24 C24 A25 B25 C25 A26 B26 C26 A27 B27 C27 A28 B28 C28 A29 B29 C29 A30 B30 C30 A31 B31 C31 A32 B32 C32 J2 96 PIN FEMALE EURO DIN CONNECTOR V V 5V R10 not used Q1 MMBT2222A R1 330 D6 1N5227 3 6V 1 2 3 4 5 6 7 8 24 23 22 21 20 19 18 17 ADC12010 ADC12020 ADC12040 or ADC12L063 V REF V IN V IN AGND V A V A AGND PD D8 D7 D6 DR V D DR GND D5 D4 D3 32 31 30 29 28 27 26 2...

Page 9: ...12L063 Type 1206 25 R2 R10 R19 R2 R19 no exist not used n a 26 1 R4 0 shorting strap n a 27 2 R5 R18 100 5 Type 1206 28 2 R6 R17 47 5 Type 1206 29 2 R7 R8 33 5 47Ω for ADC12010 12020 Type 1206 30 2 R9 R13 200 5 Type 1206 31 2 R11 R15 10k 5 Type 1206 32 1 R12 470 5 Type 1206 33 1 R16 not used on ADC12L063 1K 5 Type 1206 34 1 R20 100k 5 Type 1206 35 1 R21 1K 5 Type 1206 36 R22 R23 R24 R25 not popula...

Page 10: ...ly voltage TP 3 Positive input signal to the ADC Vin TP 4 Negative input signal to the ADC Vin TP 5 Signal Input test point TP 6 Power Down active high input TP 7 ADC clock frequency monitor TP 8 5V power supply for ADC12040 12010 12020 or 3 3V for ADC12L063 TP 9 5V power supply for the Digital Interface Board if used TP 10 Optional negative power supply for breadboard area TP 20 Output Enable inp...

Page 11: ...ADC output D2 B17 ADC output D3 C17 ADC output D4 B18 ADC output D5 C18 ADC output D6 B19 ADC output D7 C19 ADC output D8 B20 ADC output D9 C20 ADC output D10 B21 ADC output D11 C21 GND A1 thru A24 A28 B28 C28 A31 B31 C31 ADC Output Enable C12 not used External clock input B23 Reserved signal B22 C22 C23 Reserved power A25 A26 B25 B26 C25 C26 5V Logic Power Supply to Digital Interface Board Reserv...

Page 12: ...MICONDUCTOR CORPORATION As used herein 1 Life support devices or systems are devices or systems which a are intended for surgical implant into the body or b support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user 2 A critical component is any com...

Reviews: