![background image](http://html1.mh-extra.com/html/national-instruments/scxi-1303/scxi-1303_installation-manual_3472613008.webp)
SCXI-1303 Installation Guide
8
©
National Instruments Corporation
5.
Connect the wires to the screw terminals by inserting the stripped end
of the wire fully into the terminal. No bare wire should extend past the
screw terminal. Exposed wire increases the risk of shorting and
causing a failure.
6.
Tighten the screw terminal to a torque of 5–7 in.-lb.
7.
Connect your shield or earth ground to the earth ground solder lug.
8.
Reinstall the strain-relief bar and tighten the strain-relief screws.
9.
Reinstall the top cover and tighten the top cover screws.
10. Connect the terminal block to the module front connector as explained
in the Installation section later in this guide.
Figure 3 shows the SCXI-1303 terminal block parts locator diagram.
Figure 3.
SCXI-1303 Parts Locator Diagram
1
Strain Relief Bar
2
Strain Relief Screws
3
Earth Ground
Solder Lug
4
Mating Connector
5
Thumbscrew
6
Top Cover Screws
7
Top Cover
2
7
3
6
4
5
1
Back View
Front View