background image

©

 National Instruments Corporation

5

NI sbRIO-9601/9602/9602XT User Guide

I/O and Other Connectors on the NI sbRIO Device

Figure 4 shows the locations of parts on the NI sbRIO device.

Figure 4.  

NI sbRIO-9601/9602/9602XT Parts Locator Diagram

1

J11, Connector for C 

S

eries Module 

3

2

P5, 

3

.

3

 V Digital I/O

3

Plated Mounting Holes

4

J10, Connector for C 

S

eries Module 2

5

P4, 

3

.

3

 V Digital I/O

6

J9, Connector for C 

S

eries Module 1

7

DIP 

S

witches

8

Backup Battery

9

P2, 

3

.

3

 V Digital I/O

10 J5, RJ-45 Ethernet Port
11 J1, R

S

-2

3

S

erial Port

12 Reset Button
1

3

P1, Ground Lug

14 LEDs
15 J

3

, Power Connector

16 P

3

3

.

3

 V Digital I/O

11

10

12

13

14

15

8

9

16

1

2

4

3

3

3

3

3

3

3

5

6

7

3

Summary of Contents for sbRIO-9601

Page 1: ...uments sbRIO 9602 Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com modular systems national instruments compactrio controlle...

Page 2: ...tages may be present Caution National Instruments makes no product safety electromagnetic compatibility EMC or CE marking compliance claims for NI sbRIO devices The end product supplier is responsible...

Page 3: ...Module LabVIEW FPGA Module NI RIO Hardware Requirements You need the following hardware to use the NI sbRIO device NI sbRIO 9601 9602 9602XT 19 30 VDC power supply Ethernet cable Dimensions This secti...

Page 4: ...450 11 43 7X 0 134 3 4 0 140 3 56 0 080 2 03 0 000 0 0 327 8 31 0 469 11 91 8 200 208 28 0 000 0 0 286 7 26 0 940 23 88 1 107 28 12 2 091 53 11 4 017 102 03 5 001 127 03 6 927 175 95 7 911 200 94 8 20...

Page 5: ...ches Millimeters Note To maintain isolation clearances on the C Series modules do not use mounting hardware larger than 0 240 in 6 1 mm in diameter and maintain an air gap of at least 0 200 in 5 0 mm...

Page 6: ...gram 1 J11 Connector for C Series Module 3 2 P5 3 3 V Digital I O 3 Plated Mounting Holes 4 J10 Connector for C Series Module 2 5 P4 3 3 V Digital I O 6 J9 Connector for C Series Module 1 7 DIP Switch...

Page 7: ...ble 1 NI sbRIO Connector Descriptions Connector Description Manufacturer and Part Number Recommended Mating Connector J3 Power 2 position MINI COMBICON header and plug 0 285 in 7 24 mm high Phoenix Co...

Page 8: ...GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND D GND Port5 DIO1 Port5 DIO2 Port5 DIO4 Port5 DIO5 Port5 DIO6 Port5 DIO7 Port5 DIO0 Port5 DIO3 Port5 DIO8 Port6 DIO9 Port6 D...

Page 9: ...5 V D GND 5 V D GND D GND Port7 DIO6 Port7 DIO7 Port8 DIO9 Port8 DIO0 Port8 DIO1 Port8 DIO2 Port7 DIO5 Port7 DIO8 Port8 DIO3 Port8 DIO4 Port8 DIO5 Port8 DIO6 Port8 DIO7 Port8 DIO8 Port9 DIO9 Port9 DI...

Page 10: ...Port2 DIOCTL D GND D GND D GND D GND D GND Port0 DIO1 Port0 DIO2 Port0 DIO4 Port0 DIO5 Port0 DIO6 Port0 DIO7 Port0 DIO0 Port0 DIO3 Port0 DIO8 Port1 DIO9 Port1 DIO0 Port1 DIO1 Port1 DIO2 Port1 DIO3 Po...

Page 11: ...D GND D GND D GND D GND D GND 5 V D GND 5 V D GND D GND Port7 DIO1 Port7 DIO2 Port3 DIO9 Port3 DIO0 Port3 DIO1 Port3 DIO2 Port7 DIO0 Port7 DIO3 Port3 DIO3 Port3 DIO4 Port3 DIO5 Port3 DIO6 Port3 DIO7 P...

Page 12: ...system ground external to the NI sbRIO device Do not use the NI sbRIO device as the common system grounding point Significant currents traversing through the NI sbRIO grounds can result in digital co...

Page 13: ...er consumption during execution and add 20 to your estimates to account for transient and startup conditions Note Select a high quality power supply with less than 20 mV ripple The NI sbRIO device has...

Page 14: ...lication each time it is booted Refer to the Running a Stand Alone Real Time Application RT Module topic of the LabVIEW Help for more information Boot Options Table 2 lists the reset options available...

Page 15: ...e and time from the internal real time clock at startup This synchronization provides timestamp data to the device Configuring DIP Switches Figure 11 DIP Switches All of the DIP switches are in the OF...

Page 16: ...y One stop bit No flow control Keep this switch in the OFF position during normal operation If CONSOLE OUT is enabled LabVIEW RT cannot communicate with the serial port IP RESET Switch Push the IP RES...

Page 17: ...ent a LabVIEW FPGA application from loading at startup The NO FPGA switch overrides the options described in the Boot Options section After startup you can download bit files to flash memory from a La...

Page 18: ...TUS LED The STATUS LED is off during normal operation The NI sbRIO device indicates specific error conditions by flashing the STATUS LED a certain number of times as shown in Table 3 Table 3 Status LE...

Page 19: ...ings are restored You can reconfigure the settings in MAX from a computer on the same subnet Refer to the Measurement Automation Explorer Help for more information about configuring the device Note If...

Page 20: ...resistance of R1 increases rapidly with temperature During overvoltage conditions high current flows through R1 and into the protection diodes High current causes internal heating in the posistor whic...

Page 21: ...cted directly to the internal 5 V power plane of the NI sbRIO device The 5 V source has current limiting and overvoltage clamps Nevertheless sudden current steps and noisy loads can inject high freque...

Page 22: ...01 and NI sbRIO 9602 Network Network interface 10BaseT and 100BaseTX Ethernet Compatibility IEEE 802 3 Communication rates 10 Mbps 100 Mbps auto negotiated Maximum cabling distance 100 m segment RS 23...

Page 23: ...linx Spartan 3 Reconfigurable FPGA Number of logic cells NI sbRIO 9601 17 280 NI sbRIO 9602 9602XT 46 080 Available embedded RAM NI sbRIO 9601 432 kbits NI sbRIO 9602 9602XT 720 kbits 3 3 V Digital I...

Page 24: ...1 9602 at 20 to 55 C 20 V NI sbRIO 9602XT at 20 to 85 C 20 V at 40 to 20 C 7 V Posistor PRG18BB330MS1RB from Murata Maximum peak abnormal condition current 760 mA Maximum hold current at 25 C 36 mA Ma...

Page 25: ...2XT User Guide 24 ni com Resistance temperature characteristics typical curve Resistance Temperature Characteristics Typical Curve Resistance Change R R25 Temperature C 40 20 0 20 40 60 80 100 120 140...

Page 26: ...t 1 8 A Power connector internal fuse 2 A non replaceable Total power requirement Pint PDIO P5V PCSer where Pint is the consumption by sbRIO internal operation PDIO is the consumption by the 3 3 V DIO...

Page 27: ...t as follows Pint 6 0 W PCSer 1 10 W PDIO 1 28 W P5V 0 00 W Adding 20 for transient conditions 8 38 W 1 2 10 06 W Total power requirement 10 06 W Backup battery 3 V lithium coin cell BR2032 40 to 85 C...

Page 28: ...nter For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment we...

Page 29: ...0 5 to 0 6 N m 4 4 to 5 3 lb in Weight 198 45 g 7 0 oz Cabling Table 4 shows the standard Ethernet cable wiring connections for both normal and crossover cables Table 4 Ethernet Cable Wiring Connectio...

Page 30: ...upport in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States contact your local br...

Page 31: ...ective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your media or ni com patents 2008 2010 Natio...

Reviews: