background image

February 2007

373308G-01

GETTING STARTED GUIDE

NI Digital Waveform 
Generator/Analyzer

This document explains how to install, configure, and test a National 
Instruments digital waveform generator/analyzer and how to program it 
using NI-HSDIO driver software. This document applies specifically to the 
following devices:

NI PXI/PCI-6541/6542 (NI 654

x

)

NI PXI/PCI-6551/6552 (NI 655

x

)

NI PXI/PCI-6561/6562 (NI 656

x

)

For more information about features and programming, refer to the 

NI Digital Waveform Generator/Analyzer Help

 at 

Start»Programs»

National Instruments»NI-HSDIO»Documentation»NI Digital 
Waveform Generator/Analyzer Help

.

Refer to the specifications

 

document that ships with your device for detailed 

specifications.

The most recent versions of product documentation are available at 

ni.com/manuals

. Visit 

ni.com/idnet

 for the latest version of NI-HSDIO 

driver software.

Contents

Conventions ...............................................................................................2
1. Verifying the System Components ........................................................4
2. Unpacking ..............................................................................................4
3. Verifying the Kit Contents.....................................................................4

Documentation...................................................................................5
EMI Gasket (NI PXI-655

x

 Only).......................................................5

4. Installing the Software ...........................................................................5

Choose and Install Your ADE ...........................................................5
Install NI-HSDIO...............................................................................5
(Optional) Install the NI Digital Waveform Editor ...........................6

Summary of Contents for NI

Page 1: ...Digital Waveform Generator Analyzer Help at Start Programs National Instruments NI HSDIO Documentation NI Digital Waveform Generator Analyzer Help Refer to the specifications document that ships with...

Page 2: ...n ellipsis represent a range of values associated with a bit or signal name for example AO 3 0 The symbol leads you through nested menu items and dialog box options to a final action The sequence File...

Page 3: ...ames of disk drives paths directories programs subprograms subroutines device names functions operations variables filenames and extensions monospace bold Bold text in this font denotes the messages a...

Page 4: ...uch the exposed pins of connectors To avoid ESD damage in handling the device take the following precautions Ground yourself with a grounding strap or by touching a grounded object Touch the antistati...

Page 5: ...sket Refer to step 5 Installing the Hardware for more information about the gasket 4 Installing the Software This section describes the software installation process for the NI digital waveform genera...

Page 6: ...appears that asks if you want to restart shut down or restart later Select Restart 4 If you are using a system running the LabVIEW Real Time Module download NI HSDIO to the target using MAX Refer to...

Page 7: ...out re enabling your device refer to the I Received a Thermal Shutdown Error section in Appendix B Troubleshooting Installing a PXI Module To install the module refer to Figure 1 and complete the foll...

Page 8: ...78678 01 available for purchase at ni com 11 Plug in and power on the chassis NI PXI modules are sensitive instruments that should be handled carefully Do not expose the module to temperatures or humi...

Page 9: ...vice To install your PCI device complete the following steps 1 Power off and unplug the PC 2 If the PC has multiple fan speed settings ensure that the fans are set to the highest setting 3 Remove the...

Page 10: ...uring and Testing in MAX To configure and test the NI digital waveform generator analyzer in MAX complete the following steps 1 Launch MAX to configure and test the digital waveform generator analyzer...

Page 11: ...e digital device You need this information when you program the device Using the Test Panel to Generate and Acquire Data To verify your device configuration use the device test panel in MAX to generat...

Page 12: ...in the following figure Because the data channels on the NI digital waveform generator analyzer are bidirectional while the data is being continuously generated on all of the channels as in the previo...

Page 13: ...tor analyzer Note Whether you use NI cables and accessories or design your own you should properly terminate cables to avoid improper measurements due to signal reflections overshoot and undershoot Re...

Page 14: ...erator Analyzer 2 NI SHC68 C68 D2 Cable 3 NI CB 2162 Accessory 1 PXI Chassis with NI Digital Waveform Generator Analyzer 2 NI SMB 2163 Accessory 3 NI SHC68 C68 D2 Cable NI PXI 6551 50 MHz Digital I O...

Page 15: ...s to various types of devices and circuits for interfacing testing or analysis This cable offers connectivity similar to that found on a typical logic analyzer so you can use it in logic analyzer type...

Page 16: ...his cable offers connectivity similar to that found on a typical logic analyzer so you can use it in logic analyzer type applications The cable is shown in Figure 8 1 NI Digital Waveform Generator Ana...

Page 17: ...ctor for the VHDCI cable from NI part number 778914 01 For more information about creating these custom accessories refer to the Interfacing to the NI Digital Waveform Generator Analyzer using the VHD...

Page 18: ...ation an NI digital waveform generator analyzer generates data through a matched impedance system that consists of a 50 output impedance a 50 cable and a 50 accessory Figure 9 shows a diagram of such...

Page 19: ...operations and attributes that exercise all the functionality of the device including configuration control and other device specific functions Information about programming with NI HSDIO is availabl...

Page 20: ...or your first NI HSDIO program select to Start All Programs Program Files NI HSDIO Examples NI Example Finder You can also use the NI Example Finder to search or browse examples NI HSDIO examples are...

Page 21: ...3 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO 31 GND DIO 29 GND DIO 27 G...

Page 22: ...3 45 47 49 51 53 55 57 59 61 63 65 DIO 0 31 Data Bidirectional digital I O data channels 0 through 31 26 30 64 PFI 1 3 Control Input terminals to the NI 654x for external triggers or output terminals...

Page 23: ...25 26 27 28 29 30 31 32 33 34 RESERVED GND RESERVED GND RESERVED GND RESERVED RESERVED RESERVED GND RESERVED GND DIO 19 GND DIO 17 GND DIO 15 GND DIO 13 GND DIO 11 GND DIO 9 GND DIO 7 PFI 1 DIO 5 GND...

Page 24: ...s those described in Tables 5 and 6 Table 2 NI 655x DDC Connector Pins Pins Signal Name Signal Type Signal Description 33 DDC CLKOUT Control Output terminal for the exported Sample clock 67 STROBE Con...

Page 25: ...11 GND DIO 12 GND DIO 13 GND DIO 14 GND DIO 15 GND STROBE GND DDC CLK OUT LVDS GND RESERVED NC GND DDC CLK OUT LVPECL GND PFI_1 PFI_2 PFI_3 GND RESERVED NC DIO 0 DIO 1 DIO 2 DIO 3 DIO 4 DIO 5 DIO 6 D...

Page 26: ...Complementary external Sample clock source which can be used for dynamic acquisition 14 17 20 23 26 29 32 35 38 41 44 47 50 53 56 59 DIO 0 15 Data Bidirectional digital I O data channels 0 through 15...

Page 27: ...O 2 GND DIO 3 GND DIO 4 GND DIO 5 GND DIO 6 GND DIO 7 GND DIO 8 GND DIO 9 GND DIO 10 GND DIO 11 GND DIO 12 GND DIO 13 GND DIO 14 GND DIO 15 GND STROBE GND DDC CLK OUT LVDS GND RESERVED NC GND DDC CLK...

Page 28: ...gers or output terminal from the device for events CLK OUT Reference Clock Output Control Terminal for the exported PLL Reference clock or the exported Sample clock Table 5 ACTIVE LED Indicators Color...

Page 29: ...damaged device 4 Reinstall the PXI module using the procedure described in step 5 Installing the Hardware 5 Power on your PXI chassis 6 Verify the device appears in MAX 7 Reset the device in MAX and p...

Page 30: ...hat your device is effectively cooled 3 Call niHSDIO_ResetDevice NI HSDIO Reset Device VI or perform a device reset in MAX For more information about performing a device reset in MAX refer to step 6 C...

Page 31: ...cated at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United Stat...

Page 32: ...National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer t...