National Instruments NI WLS-9000 Series Getting Started Manual Download Page 11

© 

National Instruments Corporation

11

NI-DAQmx for NI WLS/ENET-9163 Getting Started Guide

Note

If after clicking 

Save Settings

 your device becomes unresponsive, 

press the RESET button on the NI WLS/ENET-9000 Series device for 
five seconds to return the device user configuration to the factory 
defaults and reconnect the Ethernet cable. Refer to the 

Troubleshooting 

Device Connectivity

 section for more network connection tips.

Wired Configuration

—To use your NI WLS/ENET-9000 Series device with 

an Ethernet cable, select the Wired Configuration tab (for NI WLS-9000 
Series devices) or the Configuration tab (for NI ENET-9000 Series devices) 
and complete the following steps.

a. Select 

DHCP + Link-Local

DHCP

Static

, or 

Link-Local

 from the 

Obtain IP Address Through pull-down menu.

If you selected DHCP from the Obtain IP Address Through pull-down 
menu, the IP Address, Subnet Mask, Gateway, DNS Server fields are 
automatically populated after you save your settings. Otherwise, ask your 
network administrator for the correct settings.

b. Click 

Save Settings

. The Apply Changes? alert opens. Click 

OK

.

For more information about MAX configuration, refer to the 

NI-DAQmx Help

accessible from 

Start»All Programs»National Instruments»NI-DAQ

.

Summary of Contents for NI WLS-9000 Series

Page 1: ...that the device is working properly Refer to the NI WLS ENET 9163 User Guide and Specifications and your C Series I O module user guide for information about how to use your NI WLS ENET 9000 Series de...

Page 2: ...and complete the instructions including rebooting the computer For troubleshooting instructions use the Hardware Installation Configuration Troubleshooter at ni com support install Step 2 Unpack and...

Page 3: ...any protective covers from the C Series I O module connector 2 Align the C Series I O module with the NI WLS ENET 9163 carrier 3 Squeeze the latches and insert the C Series I O module into the NI WLS...

Page 4: ...the supplied antenna as shown in Figure 3 Figure 3 NI WLS 9163 Carrier Antenna Assembly N A T IO N A L IN S T R U M E N T S RES ET LINK ACT GND GND PR0 PR1 10 1 00 INPU T 9 30 V 4 5 W MAX V C NI WL S...

Page 5: ...ter or other 9 30 VDC power source The POWER and STATUS LEDs light The POWER LED will light as long as power is being supplied to the NI WLS ENET 9000 Series device Refer to the NI WLS ENET 9163 User...

Page 6: ...w and click Add Selected Devices to add the device to MAX The device will be listed under Network Devices in the configuration tree If your device does not appear in Available Devices wait until the P...

Page 7: ...If your device still does not appear contact your system administrator to confirm that the network is working and that a firewall is not interfering with discovery For more information about the port...

Page 8: ...wing information in the General Network Settings section Hostname The default is WLS serial number or ENET serial number This field is limited to 32 characters Comment Use this field to enter notes su...

Page 9: ...IP Address Subnet Mask Gateway DNS Server fields are automatically populated after you save your settings Otherwise ask your network administrator for the correct settings Select or enter the name of...

Page 10: ...and Password fields Ask your network administrator for the correct settings c Click Save Settings The Apply Changes alert opens Click OK The WLS LINK LED lights on the device indicating a connected a...

Page 11: ...able select the Wired Configuration tab for NI WLS 9000 Series devices or the Configuration tab for NI ENET 9000 Series devices and complete the following steps a Select DHCP Link Local DHCP Static or...

Page 12: ...gnal lines to the terminal block or accessory terminals to your device The following table lists the different ways to access device pin assignments pinouts Location How to Access Pinout MAX Right cli...

Page 13: ...erfaces Network Devices 2 Right click your device and select Test Panels to open a test panel for the selected device 3 Click the tabs at the top and Start to test the device functions or Help for ope...

Page 14: ...data acquisition in your application software refer to the tutorials listed in the following table Application Tutorial Location LabVIEW Go to Help Search the LabVIEW Help Next go to Getting Started w...

Page 15: ...sual Basic and ANSI C examples go to ni com info and enter the info code daqmxexp For additional examples refer to zone ni com To run examples without hardware installed use an NI DAQmx simulated devi...

Page 16: ...names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your...