NI-DAQmx for NI WLS/ENET-9163 Getting Started Guide
10
ni.com
•
Select the type of authentication (
Open
,
WEP
,
WPA Pre-Shared
Key
,
WPA2 Pre-Shared Key
,
WPA Enterprise
,
WPA2
Enterprise
) used on the wireless network from the Authentication
Type pull-down menu. Contact your network administrator for the
appropriate settings. For more information about the resulting fields,
refer to the
NI-DAQmx Help
, accessible from
Start»All Programs»
National Instruments»NI-DAQ
.
•
Select
LEAP
,
PEAP
,
TTLS
, or
TLS
from the EAP Type pull-down
menu.
If you selected LEAP or PEAP from the EAP Type pull-down menu,
the you must enter the correct login and password in the Username
and Password fields. Ask your network administrator for the correct
settings.
c. Click
Save Settings
. The Apply Changes? alert opens. Click
OK
.
The WLS LINK LED lights on the device indicating a connected and
authenticated network link.
d. If Link Status (Wireless) in the Device Information section of the Network
Config tab is listed as
Down
, click the
Refresh
button a few times. Link
Status (Wireless) must be listed as
Up
before you can disconnect the
Ethernet cable.
When the device is properly configured, you can connect the device to the
wireless network that you configured it for by disconnecting the Ethernet
cable from the device and clicking the
Refresh
button so that the Link Status
(Wired) changes to
Down
. For more information about MAX configuration,
refer to the
NI-DAQmx Help
, accessible from
Start»All Programs»National
Instruments»NI-DAQ
.