14. Power on the chassis.
15. Verify that the controller boots. If it does not boot, refer to the 

What If the NI PXIe-8840 

Does Not Boot?

 section later in this guide.

Figure 2 shows an NI PXIe-8840 controller installed in the system controller slot of an 
NI PXIe-1082 chassis.

Figure 2.  

NI PXIe-8840 Controller Installed in a PXI Express Chassis 

How to Remove the Controller from the PXI Express 
Chassis

The NI PXIe-8840 controller is designed for easy handling. To remove the unit from the 
PXI Express chassis:
1.

Power off the chassis.

2.

Remove any cables that may be attached to the controller front panel.

3.

Unscrew the four bracket-retaining screws in the front panel.

4.

Press the injector/ejector handle down.

5.

Slide the unit out of the chassis.

What If the NI PXIe-8840 Does Not Boot?

Several problems can cause a controller not to boot. Here are some things to look for and 
possible solutions.

Things to Notice

Which LEDs come on? The 

Power OK

 LED should stay lit. The 

Drive

 LED should blink 

during boot as the disk is accessed. 