background image

NI 653x Cable Adapter User Guide

14

ni.com

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 0 662 45 79 90 0, 
Belgium 32 0 2 757 00 20,  Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 6555 7838, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 385 0 9 725 725 11,  France 33 0 1 48 14 24 24, 
Germany 49 0 89 741 31 30, India 91 80 41190000, 
Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, 
Korea 82 02 3451 3400,  Lebanon 961 0 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, 
Netherlands 31 0 348 433 466, New Zealand 0800 553 322, 
Norway 47 0 66 90 76 60, Poland 48 22 3390150, 
Portugal 351 210 311 210, Russia 7 095 783 68 51, 
Singapore 1800 226 5886, Slovenia 386 3 425 4200, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 0 8 587 895 00,  Switzerland 41 56 200 51 51, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, 
United Kingdom 44 0 1635 523545

Summary of Contents for NI 6535

Page 1: ...e adapter is also compatible with the NI 654x and NI 655x digital pattern generator analyzer devices For best signal integrity NI recommends using the NI 6535 6536 6537 devices with newer accessories...

Page 2: ...ferent aspects of the device The titles and location of the documents vary based on the driver that supports the NI device but you should have the following types of documentation Getting Started Guid...

Page 3: ...gure 1 NI 653x Cable Adapter Parts Locator Diagram 1 Enclosure Base 2 Jacksockets M2 5 Screw 2 56 Socket 3 68 Pin DAQ Connector 4 Enclosure Top Cover 5 M2 5 x 6 mm Philips Flathead Countersunk Screws...

Page 4: ...ot liable for damage resulting from improper connections Refer to Figure 2 as you complete the following steps to install the cable adapter 1 Insert the cable into the cable adapter 2 Tighten the cabl...

Page 5: ...its enclosure complete the following steps 1 Remove the screws from the cable adapter enclosure top cover as shown in Figure 3 Figure 3 Remove Screws from the Enclosure 2 Remove the enclosure top cov...

Page 6: ...0 7 from the NI 6533 6534 68 pin DAQ connector are connected to an 8 position screw terminal PFI channels must be manually connected through screw terminals for flexibility and to ensure correct sign...

Page 7: ...e 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO...

Page 8: ...41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 5 V PFI 2 PFI 6 PFI 0 PFI 4 PFI 5 PFI 1 PFI 7 PFI 3 P0 0 GND P0 3 P0 4 GND P0 7 P1 0 P1 1 GND R GND GND P1 6 P1 7 P2...

Page 9: ...0 7 or P3 0 7 on a 68 pin DAQ connector PFI 0 5 Programmable functional interface PFI channels 0 through 5 6 position screw terminal J4 GND Ground reference for signals RESERVED These channels are res...

Page 10: ...hipped with the NI high speed DIO device NI is not liable for any damage resulting from such signal connections Table 3 shows the relationship between PFI channels and the termination sockets Note Ref...

Page 11: ...NI 6533 6534 Without changing the fixture setup the adapter and software can be changed to maintain functionality The NI 653x cable adapter can be configured using 22 to 26 gauge wire as shown in Fig...

Page 12: ...34 Burst Handshaking Application Figure 9 shows the changes made to this LabVIEW VI to accommodate the NI 653x cable adapter connections and provide compatibility with the previous application using a...

Page 13: ...Physical Dimensions 62 7 69 3 16 7 mm 2 47 2 73 0 66 in I O connectors 68 pin VHDCI connector 6 position screw terminal 8 position screw terminal 68 pin DAQ connector Recommended wire gage 22 26 AWG R...

Page 14: ...support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 21 6...

Page 15: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: