background image

©

 National Instruments Corporation

7

NI 653x Cable Adapter User Guide

Note

Refer to the help file for your device for information about the number of available 

DIO channels on your device. DIO <20..31> or PFI_0 may not be applicable to your 
device.

Figures 5 and 6 show pinouts for the VHDCI connector and 68-pin DAQ 
connector, respectively.

Figure 5.  

VHDCI Connector Pinout (NI SHC68-C68-D2 or NI C68-C68-D4 Cable)

35 
36 
37 
38 
39 
40 
41 
42 
43 
44 
45 
46 
47 
48 
49 
50 
51 
52 
53 
54 
55 
56 
57 
58 
59 
60 
61 
62 
63 
64 
65 
66 
67 
68









10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 
26 
27 
28 
29 
30 
31 
32 
33 
34

DIO 31

GND

DIO 29

GND

DIO 27

GND

DIO 25

RESERVED

DIO 23

GND

DIO 21

GND

DIO 19

GND

DIO 17

GND

DIO 15

GND

DIO 13

GND

DIO 11

GND

DIO 9

GND

DIO 7

PFI 1

DIO 5

GND

DIO 3

PFI 3

DIO 1

GND

DDC CLK OUT/PFI_4

GND

DIO 30
GND
DIO 28
GND
DIO 26
GND
DIO 24
GND
DIO 22
GND
DIO 20
GND
DIO18
GND
DIO 16
GND
DIO 14
RESERVED/PFI_0
DIO 12
GND
DIO 10
GND
DIO 8
GND
DIO 6
RESERVED
DIO 4
GND
DIO 2
PFI 2
DIO 0
GND
STROBE/PFI_5
GND

Summary of Contents for NI 6535

Page 1: ...e adapter is also compatible with the NI 654x and NI 655x digital pattern generator analyzer devices For best signal integrity NI recommends using the NI 6535 6536 6537 devices with newer accessories...

Page 2: ...ferent aspects of the device The titles and location of the documents vary based on the driver that supports the NI device but you should have the following types of documentation Getting Started Guid...

Page 3: ...gure 1 NI 653x Cable Adapter Parts Locator Diagram 1 Enclosure Base 2 Jacksockets M2 5 Screw 2 56 Socket 3 68 Pin DAQ Connector 4 Enclosure Top Cover 5 M2 5 x 6 mm Philips Flathead Countersunk Screws...

Page 4: ...ot liable for damage resulting from improper connections Refer to Figure 2 as you complete the following steps to install the cable adapter 1 Insert the cable into the cable adapter 2 Tighten the cabl...

Page 5: ...its enclosure complete the following steps 1 Remove the screws from the cable adapter enclosure top cover as shown in Figure 3 Figure 3 Remove Screws from the Enclosure 2 Remove the enclosure top cov...

Page 6: ...0 7 from the NI 6533 6534 68 pin DAQ connector are connected to an 8 position screw terminal PFI channels must be manually connected through screw terminals for flexibility and to ensure correct sign...

Page 7: ...e 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO...

Page 8: ...41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 5 V PFI 2 PFI 6 PFI 0 PFI 4 PFI 5 PFI 1 PFI 7 PFI 3 P0 0 GND P0 3 P0 4 GND P0 7 P1 0 P1 1 GND R GND GND P1 6 P1 7 P2...

Page 9: ...0 7 or P3 0 7 on a 68 pin DAQ connector PFI 0 5 Programmable functional interface PFI channels 0 through 5 6 position screw terminal J4 GND Ground reference for signals RESERVED These channels are res...

Page 10: ...hipped with the NI high speed DIO device NI is not liable for any damage resulting from such signal connections Table 3 shows the relationship between PFI channels and the termination sockets Note Ref...

Page 11: ...NI 6533 6534 Without changing the fixture setup the adapter and software can be changed to maintain functionality The NI 653x cable adapter can be configured using 22 to 26 gauge wire as shown in Fig...

Page 12: ...34 Burst Handshaking Application Figure 9 shows the changes made to this LabVIEW VI to accommodate the NI 653x cable adapter connections and provide compatibility with the previous application using a...

Page 13: ...Physical Dimensions 62 7 69 3 16 7 mm 2 47 2 73 0 66 in I O connectors 68 pin VHDCI connector 6 position screw terminal 8 position screw terminal 68 pin DAQ connector Recommended wire gage 22 26 AWG R...

Page 14: ...support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 21 6...

Page 15: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: