Getting Started with the NI 17xx

Install Software on the NI Smart Camera

Complete the following steps to install software from the 
development computer to the NI Smart Camera.

1. In the Remote Target Configuration Wizard, enable the 

Update Target Software

 checkbox.

2. Click the 

Browse

 button next to the 

Software Image to Install 

on the Target

 control.

3. Navigate to the Vision Builder AI software image you want to 

use, and click 

OK

. Software images provided by National 

Instruments are installed to the 

<Vision Builder AI>\

RT Images

 directory, where 

<Vision Builder AI>

 is the 

location where Vision Builder AI is installed.

4. Click 

OK

 to apply the IP configuration settings and download 

software to the smart camera.

5. Click 

OK

 to close the Remote Target Configuration Successful 

dialog box.

Acquire an Image

Complete the following steps to acquire an image using Vision 
Builder AI.

1. On the Vision Builder AI welcome screen, select the NI Smart 

Camera in the list of targets.

2. Click 

Acquire Image (Smart Camera) Example

 to open the 

image acquisition example in the Vision Builder AI 
Configuration Interface.

3. Click the 

Run State Once

 button to acquire a single image.

4. In the State Configuration Window, select the 

Acquire Image 

(Smart Camera)

 step.

5. Click the 

Edit Step

 button. The property page for the step 

opens.

6. Use the controls on the 

Main

Trigger

Lighting

, and 

Advanced

 tabs to configure any additional settings necessary 

for your application.

7. Click 

OK

 to save the step configuration.

The smart camera is now configured and acquiring images. Use 
Vision Builder AI to add and configure additional inspection steps 
to create your application. Refer to the 

Where to Go from Here

 

section for a list of documentation and other resources to help you 
set up and use the smart camera in an application.

Summary of Contents for NI 17xx Smart

Page 1: ...on about specific features and specifications of the smart camera Select Start All Programs National Instruments Vision Documentation NI IMAQ to access the NI 17xx Smart Camera User Manual after confi...

Page 2: ...communication CAT 5 cables are not guaranteed to meet the necessary electrical requirements While CAT 5 cables may appear to work at 1 000 Mbps in some installations CAT 5 cables are likely to cause i...

Page 3: ...rmation Optional Components National Instruments offers a variety of accessories for use with the NI Smart Camera including the following items Lenses 8 mm part number 780024 01 12 mm part number 7800...

Page 4: ...Connect the Lens and Lighting Complete the following steps to connect a standard C mount lens and external lighting accessories to the NI Smart Camera 1 Remove the lens cover from the smart camera 2...

Page 5: ...listed mark LPS The power supply must also meet any safety and compliance requirements for the country of use Power Only Refer to Figure 1 while completing the following steps to connect the NI deskt...

Page 6: ...cable Figure 2 Connecting the NI Smart Camera to a Third Party Power Supply 1 Connect and secure the 15 pin D SUB connector on your cable to the POWER I O connector on the smart camera 2 If you are u...

Page 7: ...hen power is first applied to the smart camera the POWER LED flashes red for one second while internal systems power up The POWER LED then lights green when power is correctly wired to the smart camer...

Page 8: ...development computer to connect through the network Caution To prevent data loss and to maintain the integrity of your Ethernet installation do not use a cable longer than 100 m National Instruments...

Page 9: ...ment computer to use a static IP address Refer to your Windows networking documentation for information about configuring a static IP address The smart camera is now connected directly to the developm...

Page 10: ...ra is configured as described in the Configuring the NI Smart Camera with Vision Builder AI section and the Configuring the NI Smart Camera with LabVIEW section other subnets can be used to access it...

Page 11: ...developing flexible and scalable applications The following add on modules are required for developing machine vision applications LabVIEW Real Time Module Programming library for developing distribut...

Page 12: ...ument and Appendix B Troubleshooting of the NI 17xx Smart Camera User Manual for information about subnets and troubleshooting smart camera configuration issues 4 Click Install Software The Remote Tar...

Page 13: ...box Acquire an Image Complete the following steps to acquire an image using Vision Builder AI 1 On the Vision Builder AI welcome screen select the NI Smart Camera in the list of targets 2 Click Acqui...

Page 14: ...Release and Upgrade Notes for installation instructions and information about getting started with the LabVIEW Real Time Module Documentation for the LabVIEW Real Time Module is available by selecting...

Page 15: ...information about subnets and troubleshooting smart camera configuration issues 3 In the Name field enter a name for the device Use the Comment field to enter any additional information or a brief de...

Page 16: ...stall Software on the NI Smart Camera Complete the following steps to install software from the development computer to the NI Smart Camera 1 In the Remote Systems branch of the MAX configuration tree...

Page 17: ...o create your application Refer to the Where to Go from Here section for a list of documentation and other resources to help you set up and use the smart camera in an application Where to Go from Here...

Page 18: ...d Additional Resources for LabVIEW Users Documentation for LabVIEW and the LabVIEW Real Time Module is available from the Help menu on the LabVIEW toolbar You can access documentation for the NI Visio...

Page 19: ...or to removing covers or shields If the device is rated for use with hazardous voltages 30 Vrms 42 4 Vpk or 60 Vdc it may require a safety earth ground connection wire Refer to the device specificatio...

Page 20: ...ry establishes standardized impulse withstand voltage levels that commonly occur in electrical distribution systems The following is a description of Measurement Categories Measurement Category I is f...

Page 21: ...to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development se...

Page 22: ...Poland 48 22 328 90 10 Portugal 351 210 311 210 Russia 7 495 783 6851 Singapore 1800 226 5886 Slovenia 386 3 425 42 00 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switz...

Page 23: ...fer to the Trademark Information at ni com trademarks for other National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective compa...

Reviews: