Appendix B Error Codes
Measure Data Acquisition User Manual
B-6
© National Instruments Corporation
-10254
DAQCardConfErr
The DAQCard cannot be configured
because 1) the correct version of the card
and socket services software is not
installed, 2) the card in the PCMCIA
socket is not a DAQCard, or 3) the base
address and/or interrupt level requested
are not available according to the card
and socket services resource manager.
Try different settings or use AutoAssign
in the NI-DAQ configuration utility.
-10256
dmaChannel1Error
Bad DMA channel 1 specified in the
configuration utility or by the operating
system.
-10257
baseAddressError
Bad base address specified in the
configuration utility.
-10258
dmaChannel1Error
Bad DMA channel 1 specified in the
configuration utility or by the operating
system.
-10259
dmaChannel2Error
Bad DMA channel 2 specified in the
configuration utility or by the operating
system.
-10260
dmaChannel3Error
Bad DMA channel 3 specified in the
configuration utility or by the operating
system.
-10340
noConnectErr
No RTSI signal/line is connected, or the
specified signal and the specified line are
not connected.
-10341
badConnectErr
The RTSI signal/line cannot be
connected as specified.
-10342
multConnectErr
The specified RTSI signal is already
being driven by a RTSI line, or the
specified RTSI line is already being
driven by a RTSI signal.
-10343
SCXIConfigErr
The specified SCXI configuration
parameters are invalid, or the function
cannot be executed with the current
SCXI configuration.
-10360
DSPInitErr
The DSP driver was unable to load the
kernel for its operating system.