Chapter 3
Local Command Set
©
National Instruments Corporation
3-21
devclass
Device class; the following values may be used:
0 = Memory Class
1 = Extended Class
2 = Message-Based
3 = Register-Based
subclass
Extended class device’s subclass
manID
Manufacturer’s ID number
modelcode
Device’s manufacturer-assigned model code
memspace
Memory space requirement:
0 = A16 only
1 = A16/A24
2 = A16/A32
membase
Memory base address
memsize
Memory size in bytes
state
Status state:
0 = Failed and not Ready
1 = Passed and not Ready
2 = Failed and Ready
3 = Passed and Ready
line status
Online/offline status:
0 = online
1 = forced offline
The program mode response format is the same for all devices. However, the console mode
response returns only the lines that are relevant. For example, memory base address and
memory size lines are not returned for A16-only memory space devices.
Example
Get RM information for a device at Logical Address 78.
RmEntry? 78