built into the product if the product is damaged in any way. If the product is
damaged, return it to NI for repair.
The FD-11634 is rated for use in DRY or WET LOCATIONS. Hazardous voltages may not be
connected to the device. A hazardous voltage is a voltage greater than 42.4 V peak voltage or
60 V DC in DRY LOCATIONS, and 22.6 V peak or 35 V DC in WET LOCATIONS.
Caution
All wiring must be insulated for the highest voltage used.
EMC Guidelines
This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits provide reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment.
This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test object,
or if the product is used in residential or commercial areas. To minimize interference with
radio and television reception and prevent unacceptable performance degradation, install and
use this product in strict accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved by NI could
void your authority to operate it under your local regulatory rules.
Electromagnetic Compatibility Notices
Refer to the following notices for cables, accessories, and prevention measures necessary to
ensure the specified EMC performance.
Notice
To ensure the specified EMC performance, operate this product only with
shielded cables and accessories.
Special Conditions for Marine Applications
Some models are approved for marine (shipboard) applications. To verify marine approval
certification for a model, visit
click the appropriate link.
Notice
In order to meet the EMC requirements for marine applications, install the
model in a shielded enclosure with shielded and/or filtered power and input/output
ports. In addition, take precautions when designing, selecting, and installing
measurement probes and cables to ensure that the desired EMC performance is
attained.
FD-11634 User Guide
|
© National Instruments
|