Chapter 2
Analog Input Timing/Control
©
National Instruments Corporation
2-101
DAQ-STC Technical Reference Manual
Internal CONVERT Mode
In the internal CONVERT mode, the START and SCAN_IN_PROG outputs are generated by
the inactive edge of the SI2 source that recognizes START. You can select the pulsewidth of
the START pulse using AI_Trigger_Length. Figure 2-33 shows the propagation delays for
START and SCAN_IN_PROG in the internal CONVERT mode.
Figure 2-33.
START Delays, Internal CONVERT
Name
Description
Minimum
Maximum
Tpfi
SI2 Source to PFI output (START)
14
56
Tbrd
SI2 Source to BRD output (START)
15
60
Tscan
SI2 Source to SCAN_IN_PROG
16
56
Tspfi
SI2 Source to PFI output
(SCAN_IN_PROG)
16
56
Tsbrd
SI2 Source to BRD output
(SCAN_IN_PROG)
17
61
All timing values are in nanoseconds.
SI2 Source
START
(START)
(START)
(SCAN_IN_PROG)
(SCAN_IN_PROG)
PFI7/AI_START
RTSI_BRD<2..3>
SCAN_IN_PROG
Tpfi
Tbrd
Tscan
PFI7/AI_START
Tspfi
RTSI_BRD<2..3>
Tsbrd