7. Click
Change Password
.
8. Enter and re-enter a new password.
9. Click
OK
.
10. Click
Save
.
11. Click
OK
to confirm you are changing the password.
Caution
NI cannot recover lost system passwords. If you forget the
password, you must contact NI and reformat the controller.
Installing Software on the cRIO-9066
Complete the following steps to install software on the cRIO-9066.
1. In MAX, expand your system under Remote Systems.
2. Right-click
Software
.
3. Select
Add/Remove Software
to launch the LabVIEW Real-Time Software
Wizard.
Tip
You must log in if you set a system password.
4. Select the recommended software set for your LabVIEW and NI-RIO Device
Drivers versions.
5. Click
Next
.
6. Select
NI Scan Engine
from the software add-ons.
Select any additional software to install. If you plan on using the cRIO-9066
with the LabVIEW FPGA Module, you can click
Next
. Click
NI Scan Engine
if you
plan on using the cRIO-9066 without the LabVIEW FPGA Module.
Tip
You can use this wizard at anytime to install additional software.
7. Click
Next
.
8. Verify that the summary of software to install is correct.
9. Click
Next
to start the installation.
© National Instruments
13