Figure 8.
Installing a C Series I/O Module in the Chassis
1
2
1. Insertion groove
2. Latch
2.
Squeeze the latches and insert the module into the slot.
3.
Press firmly on the connector side of the module until the latches lock the module into
place.
4.
Repeat these steps to install additional modules.
I/O Module Arrangements
NI InsightCM Server supports only dynamic C Series I/O modules, such as the NI 9232,
installed on the CMS-9024. You must fill module slots in ascending order starting with slot 1.
You cannot skip any slots but you do not have to use every slot.
Note
You must connect tachometers to the module in slot 1. Do not connect any
other sensors to the module in slot 1.
Removing I/O Modules from the Chassis
Note
Before you remove a C Series I/O module from the chassis, ensure that no
I/O-side power is connected to the module. If the system is in a nonhazardous
location, the chassis power can be on when you install modules.
Maintaining NI CMS-9024 Hardware for an NI InsightCM System
|
© National Instruments
|
9