You can measure resistors with values ranging from 100

Ω

 to 1 M

Ω

.

4.

Measure V

CC

 on AI 3 and the voltage drop across the internal 10 k

Ω

 resistor on AI 11.

5.

With these measurements, calculate the resistor value using the following formula:

Connecting Analog Output Signals

Use the AO 0 and AO 1 BNC connectors on the BNC-9920 front panel to connect analog output signals 
from channels AO 0 and AO 1 of the NI 9263 to external devices. Refer to the 

NI 9263 Operating 

Instructions and Specifications

 for information about using these signals.

Using the Function Generator

The BNC-9920 has a function generator that produces sine or triangle waveforms and TTL-compatible 
square waveforms. Use the switch below the Sine/Triangle BNC to select a sine wave or triangle wave 
output for the connector. A TTL-compatible square wave is always present at the TTL Square Wave 
BNC.

To adjust the frequency of the function generator, select your frequency range using the Frequency 
Selection switch. You can select 0.1–10 kHz, 1–100 kHz, or 13–1000 kHz. The Frequency Adjust knob 
adjusts the frequency within the preselected range for the sine or triangle wave and the TTL square wave 
outputs.

The Amplitude Adjust knob adjusts the amplitude of the sine or triangle wave output up to 4.4 V

p-p

.

Connecting User-Defined Signals

The USER 1 and USER 2 BNC connectors enable you to make a BNC connection to the digital I/O 
signal of your choice. The USER 1 and USER 2 BNC connectors are routed in the BNC-9920 to the 
USER 1 and USER 2 screw terminals, as shown in Figure 5.

Figure 5.  

USER 1 and USER 2 BNC Connections

Figure 5 shows an example of how to use the USER 1 and USER 2 BNC connectors. To access the 
DIO 16 signal from a BNC connector, connect the USER 1 screw terminal to the DIO 16 screw terminal 
with a 28–16 AWG wire.

Resistor Value

V

AI 3

V

AI 11

V

AI 11

10 k

Ω

(

)

---------------------------------------

=

U

S

ER 2 BNC

Intern

a

l

Connection

U

S

ER 1 BNC

D GND

U

S

ER 2

U

S

ER 1

D GND

Intern

a

l

Connection

Summary of Contents for BNC-9920

Page 1: ...defined BNC connectors A function generator with the following outputs Frequency adjustable TTL compatible square wave Frequency and amplitude adjustable sine wave or triangle wave Quadrature encoder...

Page 2: ...as menu items and dialog box options Bold text also denotes parameter names italic Italic text denotes variables emphasis a cross reference or an introduction to a key concept Italic text also denote...

Page 3: ...rew Terminals 22 Quadrature Encoder Knob 23 Digital I O BNC Connector DIO 8 24 Power Indicator LED E L R T T S N I NA M U N O I A S T N _ Floating Source FS _ Ground Ref Source GS AO ANALOG OUTPUTS AN...

Page 4: ...the labels 4 Connect the power end of the BNC 9920 cable to the external power supply shipped with the CompactRIO Starter Kit The power indicator LED shown in Figure 1 lights If it does not light chec...

Page 5: ...e signal sources Measuring Floating Signals To measure floating signal sources move the corresponding switch below the BNC connector to the FS position In the floating source switch position the negat...

Page 6: ...programming mode unconnected channels can cause noise on other channels In order to avoid noisy thermocouple measurements move the BNC Temp Ref switch on the BNC 9920 to the Temp Ref position For more...

Page 7: ...always present at the TTL Square Wave BNC To adjust the frequency of the function generator select your frequency range using the Frequency Selection switch You can select 0 1 10 kHz 1 100 kHz or 13 1...

Page 8: ...n in Table 1 Using the Quadrature Encoder The BNC 9920 contains a mechanical quadrature encoder circuit that produces 96 pulses per encoder revolution Two outputs PULSES and UP DN are at the screw ter...

Page 9: ...ules Note Refer to the documents shipped with the C Series modules for specifications about analog and digital I O signals Analog Input Number of channels default 8 differential Field connections defa...

Page 10: ...requency range 100 Hz to 1 MHz Frequency adjust Through the Frequency Adjust knob Rise time 250 ns Fall time 50 ns Sine triangle wave Frequency range 100 Hz to 1 MHz Frequency adjust Through the Frequ...

Page 11: ...t 1 040 g 2 lb 4 7 oz I O connector 68 pin male SCSI II type BNC connectors 15 Screw terminal plugs 31 Environment Operating temperature 0 to 50 C Storage temperature 55 to 125 C Relative humidity 5 t...

Page 12: ...ck the appropriate link in the Certification column Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that elimina...

Page 13: ...support needs For telephone support in the United States create a service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the Untied S...

Reviews: