background image

BNC-9920 Operating Instructions and Specifications

2

ni.com

Conventions

The following conventions are used in this document:

<>

Angle brackets that contain numbers separated by an ellipsis represent a range of values 
associated with a bit or signal name—for example, AO <3..0>.

»

The 

»

 symbol leads you through nested menu items and dialog box options to a final action. 

The sequence 

Options»Settings»General

 directs you to pull down the 

Options

 menu, select 

the 

Settings

 item, and select 

General

 from the last dialog box.

This icon denotes a note, which alerts you to important information.

This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, 
or a system crash.

 

When this symbol is marked on a product, refer to the 

Read Me First: Safety 

and Electromagnetic Compatibility 

document for information about precautions to take.

bold

Bold text denotes items that you must select or click in the software, such as menu items and 
dialog box options. Bold text also denotes parameter names.

italic

Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. 
Italic text also denotes text that is a placeholder for a word or value that you must supply.

monospace

Text in this font denotes text or characters that you should enter from the keyboard, sections 
of code, programming examples, and syntax examples. This font is also used for the proper 
names of disk drives, paths, directories, programs, subprograms, subroutines, device names, 
functions, operations, variables, filenames, and extensions.

What You Need to Get Started

To set up and use your BNC-9920 accessory, you need the following:

NI CompactRIO Starter Kit

CompactRIO controller and chassis or CompactRIO integrated controller and chassis

1

Installing the BNC-9920

Figure shows the front panel of the BNC-9920.

1   

NI recommends using a controller and chassis combination that supports Scan Interface programming mode. For a list of 
controllers and chassis that support Scan Interface programming mode, go to 

ni.com/info

 and enter the Info Code 

rdsoftwareversion

.

Summary of Contents for BNC-9920

Page 1: ...defined BNC connectors A function generator with the following outputs Frequency adjustable TTL compatible square wave Frequency and amplitude adjustable sine wave or triangle wave Quadrature encoder...

Page 2: ...as menu items and dialog box options Bold text also denotes parameter names italic Italic text denotes variables emphasis a cross reference or an introduction to a key concept Italic text also denote...

Page 3: ...rew Terminals 22 Quadrature Encoder Knob 23 Digital I O BNC Connector DIO 8 24 Power Indicator LED E L R T T S N I NA M U N O I A S T N _ Floating Source FS _ Ground Ref Source GS AO ANALOG OUTPUTS AN...

Page 4: ...the labels 4 Connect the power end of the BNC 9920 cable to the external power supply shipped with the CompactRIO Starter Kit The power indicator LED shown in Figure 1 lights If it does not light chec...

Page 5: ...e signal sources Measuring Floating Signals To measure floating signal sources move the corresponding switch below the BNC connector to the FS position In the floating source switch position the negat...

Page 6: ...programming mode unconnected channels can cause noise on other channels In order to avoid noisy thermocouple measurements move the BNC Temp Ref switch on the BNC 9920 to the Temp Ref position For more...

Page 7: ...always present at the TTL Square Wave BNC To adjust the frequency of the function generator select your frequency range using the Frequency Selection switch You can select 0 1 10 kHz 1 100 kHz or 13 1...

Page 8: ...n in Table 1 Using the Quadrature Encoder The BNC 9920 contains a mechanical quadrature encoder circuit that produces 96 pulses per encoder revolution Two outputs PULSES and UP DN are at the screw ter...

Page 9: ...ules Note Refer to the documents shipped with the C Series modules for specifications about analog and digital I O signals Analog Input Number of channels default 8 differential Field connections defa...

Page 10: ...requency range 100 Hz to 1 MHz Frequency adjust Through the Frequency Adjust knob Rise time 250 ns Fall time 50 ns Sine triangle wave Frequency range 100 Hz to 1 MHz Frequency adjust Through the Frequ...

Page 11: ...t 1 040 g 2 lb 4 7 oz I O connector 68 pin male SCSI II type BNC connectors 15 Screw terminal plugs 31 Environment Operating temperature 0 to 50 C Storage temperature 55 to 125 C Relative humidity 5 t...

Page 12: ...ck the appropriate link in the Certification column Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that elimina...

Page 13: ...support needs For telephone support in the United States create a service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the Untied S...