Chapter 4
Programming
©
National Instruments Corporation
4-15
10. Call
AI_Arming
to arm the analog input counter.
AI_Command_1_Register
AI SC arm = 1;
AI SI arm = 1;
AI SI2 arm = 1;
AI DIV arm = 1;
11. Install the interrupt service routine to handle the interrupt.
Interrupt_Service_Routine()
read FIFO data;
increment sample counter;
12. The function
AI_Start_The_Acquisition
starts the acquisition
process.
AI_Command_2_Register
AI START1 Pulse = 1;
13. Poll the AI FIFO not empty flag in the AI_Status_1_Register until not
empty and call the ISR.
Do
{
If (AI FIFO not empty) then
call
Interrupt_Service_Routine
;
} while (20 samples have not been read)
Example 4
Example 4 performs the same acquisition as Example 2, but with DMA.
Acquire 5 scans at a scan interval of 1ms. The scan list contains channels 5,
4, 1, and 0, repectively. The channels are configured as RSE at a gain of 1.
Within each scan, the sample interval should be 100f during the operation.
No external multiplexers are used. Use DMA to acquire the data.
In this example the programming of the DMA controller is left to the user.
1.
Perform Analog Input Example 1 Step 1.
2.
Perform Analog Input Example 1 Step 2 for each channel in the scan
list. Only channel 0 has Last channel set to 1.
3.
Perform Analog Input Example 1 Steps 3-9.
4.
Call the function
Number_of_Scans
to load the number of scans.
Joint_Reset_Register
AI configuration start = 1;
Summary of Contents for AT-AI-16XE-10
Page 131: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 2 National Instruments Corporation...
Page 132: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 3 AT MIO E Series RLPM...
Page 133: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 4 National Instruments Corporation...
Page 134: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 5 AT MIO E Series RLPM...
Page 135: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 6 National Instruments Corporation...
Page 136: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 7 AT MIO E Series RLPM...
Page 137: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 8 National Instruments Corporation...
Page 138: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 9 AT MIO E Series RLPM...
Page 139: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 10 National Instruments Corporation...
Page 140: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 11 AT MIO E Series RLPM...
Page 141: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 12 National Instruments Corporation...
Page 142: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 13 AT MIO E Series RLPM...
Page 143: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 14 National Instruments Corporation...
Page 144: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 15 AT MIO E Series RLPM...
Page 145: ...Appendix A OKI MSM82C55A Data Sheet AT MIO E Series RLPM A 16 National Instruments Corporation...
Page 146: ...Appendix A OKI MSM82C55A Data Sheet National Instruments Corporation A 17 AT MIO E Series RLPM...