Getting Started with NI 9512 and P7000 Drives
|
© National Instruments
|
27
9.
When the configuration data is downloaded, the drive performs the initialization process
with the motor as shown in Figure 18. Click
OK
.
Figure 18.
Drive and Motor Initialization
Caution
The motor shaft rotates when performing the following test.
Step 2: Test the Motor With the P7000 Tools (Optional)
Test the motor and P7000 series stepper drive configuration by jogging the motor in the negative
and positive directions using the following arrows on the Motion Toolbar.
Note
After testing the configuration settings, the RS-232 serial communication
cable between the computer and P7000 series stepper drive is no longer needed, but
you can leave it connected.
Table 14.
Motion Tool
b
ar Buttons
Icon
Behavior
Description
Jog motor negative
Jogs the motor in the negative direction
at the selected velocity.
Jog velocity toggle
Selects the active jog velocity for the
jog arrow buttons.
(L designates low speed;
H designates high speed.)
Jog motor positive
Jogs the motor in the positive direction
at the selected velocity.
Stop motion
Stops all motion.