Filter cleaning system DUSTOP
When the orange indicator light is on, the suction efficiency has lowered, or after collecting a considerable
quantity of material, a filter cleaning cycle is necessary. The filter cleaning system is best operated before
use and after prolonged operation.
First, disconnect all the accessories (flex hose, hose connector, etc.) from the dust collector.
NOTE: It is not necessary to disconnect the hose if the slide damper is present. In this case, use the
slide damper to plug the suction inlet (see next step below).
Turn on both motors and then proceed to close the suction inlet with the cap (or close slide damper if
so equipped), assuring that there is no air flow through the filtering chamber.