INSTALLATION
Our DS5 Model Controller is designed to operate with a specially designed DOOR
PHONE (see page 3).
A suitably qualified telephone technician will fit your DS5 Controller direct onto an
ANALOGUE extension of a PBX or other Multi-Line telephone system.
INSTALLATION DETAILS
1)
Connect the PBX EXTENSION port of your DS5 direct to an ANALOGUE
TELEPHONE EXTENSION socket, using the supplied telephone cable.
2)
Connect the supplied 12V power supply to your DS5, and switch the POWER
ON. Ensure that the green LED on your DS5 is illuminated.
3)
Connect the SUPPLIED DOOR PHONE to the DOOR PHONE port of your
DS5.
Run a solid core telephone cable (preferably CAT3 or CAT5) between the DS5
and the Door Phone. Maximum working distance is 300 meters.
Our DP1 Door Phone requires only 2 wires of the CAT5 cable. Our DP2-DP5 Door
Phones require 4 wires of the CAT5 cable. Your LOCK (if used) will require 2 of
these wires.
For your convenience, an interface unit with screw terminals is supplied and
should be connected to the DS5 unit using the short RJ to RJ cable that is
provided with it.
Use of the interface unit is not required unless you plan to use the internal relay
for Lock Control. If you are not using Lock Control, then you may prefer to connect
the CAT5 cable direct to the 8 pin RJ45 port of DS5. Pin connections are
described on page 11.