background image

Natcomm

 Page 5

 

 

OPERATION 

 
DS-SIP

 is designed for use with ANY IP or Cloud PBX System. It can connect to ANY 

Network Point. The IP Address of 

DS-SIP

 is then set up as an Extension and it can be 

called if required from Any Handset on the same PBX system.  

A  ‘Hot  Dial  Extension  Address’  is  set  up  on  the  PBX  system  by  the  Network 
Administrator,  to  determine  where  Intercom  calls  should  be  directed.  The  ‘Hot  Dial 
Extension Address’ is also programmed into 

DS-SIP

 using the supplied program. 

Then  when  a  visitor at the  door or gate  presses  the call button  on your  NATCOMM 
Door Phone, 

DS-SIP

  will immediately  go  ‘Off Hook’ and Dial the  Hot Dial Extension 

Number.  At  the  same  time,  DS-SIP  will  generate  a  ‘Ring  Back’  tone  to  the  Door 
Phone Intercom so that the visitor hears that they are being connected. 

A  PBX  user  can then  answer the  Door Phone Intercom  call and will be  immediately 
connected  to  the visitor so  that  they can communicate. Communication  is Loud and 
Clear. The Volume of the Door Phone can be increased or decreased via the supplied 
program. The Hang Up tone detection circuit will automatically terminate the Intercom 
call after the user hangs up

 

If you have a LOCK MECHANISM fitted, you can open a gate or door lock during a 
call to allow your visitor to enter, by simply pressing 

* *  

on your telephone keypad. 

LOCK RELAY 2

 

If  you  use  the  SECOND  LOCK  CONTROL  FACILITY  fitted,  you  can  also  open  an 
ALTERNATIVE gate or door lock during this call, by pressing 

*

 2 on your telephone.  

This command will release Gate Lock 2 until you Hang Up the telephone. 

 

 

Pressing *3 can also close the second internal relay and leave it closed. 

 

 

Pressing *4 can also open the second internal relay and leave it open.

 

 

The  SECOND LOCK  RELAY  option can  alternatively be  used to  START and  STOP 
another Device such as a VIDEO CAMERA, DISPLAY MONITOR,  RECORDER or to 
TURN  ON  and  then  TURN  OFF  a  12V  LIGHT  or  a  115V  Light  (if  a  separate  115V 
relay that is also supplied and installed by a technician or electrician).

 

 

The Other Device will be SWITCHED ON (or Activated) as soon as the Call Button is 
pressed on the supplied Door Phone and will SWITCH OFF, 01-99 seconds after the 
Door Phone call has terminated, as programmed (see pages 13-14)

 

The  Second  Relay  can  also  be  used  to  signal  other  equipment  that  a  Door  Phone 
Intercom call has been initiated.

 

Summary of Contents for DS-SIP

Page 1: ...NATCOMM USA LLC Responsible Supplier Code NC DS SIP SIP INTERCOM CONTROLLER For Technical Assistance call the Manufacturers direct ph 800 530 8645 8AM 5PM West Coast Pacific Time...

Page 2: ...plied as a complete kit ready for quick and easy installation by a technician or an end user with some IT experience Description Qty DS SIP Intercom Switch 1 12VDC Power Adaptor 1 CAT5 Network Cable R...

Page 3: ...a BNC output Marine Grade Stainless Steel face plate Touch Switch operation Blue LED Night illumination Supplied with in wall Wall Mount Box to assist installation Optional Surface Mounting Kit is ava...

Page 4: ...hones Model DPC3 for DP4 DP5 Door Phones You can alternatively use one of our Surface Mounting Kits which provides a Rain deflector See below SURFACE MOUNTING KITS Stainless Steel 304 Surface Mounting...

Page 5: ...one detection circuit will automatically terminate the Intercom call after the user hangs up If you have a LOCK MECHANISM fitted you can open a gate or door lock during a call to allow your visitor to...

Page 6: ...designed for use on PC running Windows 7 or later on your same network Install the program by double clicking the supplied Program file The program will install and a Natcomm Icon will be installed o...

Page 7: ...The Port Number if different to the default port number 5060 A Different Audio Codec if different to the default codecs Set up a to Static IP address The PBX Network Administrator may advise you to ch...

Page 8: ...ction Connect Pins 4 5 the center 2 pins of the 8 pin RJ45 socket of DS SIP to the center 2 inputs of the supplied 4 position Phoenix Plug Polarity is not important This is the Audio Pair Also connect...

Page 9: ...OPENED at any time by calling the DS SIP Extension Number and pressing The Door Gate Lock will remain UNLOCKED for 15 seconds can be 01 99 secs You do not need to receive a call from the Door Phone fi...

Page 10: ...ated at 12V 1A The polarity of the Relay connection wires is not important Lock 1 should connect to the Brown and Orange terminals Lock 2 or Device 2 should connect to the Blue and White terminals NOT...

Page 11: ...speech can only be heard in 1 direction Should you encounter one of these problems you will need to make slow careful adjustments in one direction or the other until speech can be heard in both direc...

Page 12: ...ouncement Note and cannot be used to terminate a call 2 AFTER A FIXED PERIOD OF TIME DS SIP will terminate an Intercom call after a programmable length of time The default connection time for DS SIP i...

Page 13: ...by Closing as soon as the Intercom is Triggered then you should enter a value of 01 99 in this area this value is the time in seconds that the Relay will remain closed AFTER HANG UP This facility wil...

Page 14: ...DS SIP switch is connected DS SIP switch will Answer after 1 ring you should hear 1 beep After the beep press you should hear 3 beeps This will take you into program mode 2 Change the settings as per...

Page 15: ...and IC limits If not installed and used in accordance with these instructions it may be possible that it causes interference to radio communications However there is no guarantee that the interference...

Page 16: ...ut the nature of the problem The Manufacturers obligation is solely to repair or replace the product The product may be replaced at the discretion of the Manufacturer The warrantor is not liable for a...

Reviews: