Page 8
Natcomm
DS-SIP : Door Phone Intercom Connection
DP1 INTERCOM (2 Wire Connection)
Connect the CENTER 2 PINS of the 8 pin RJ45 socket of
DS-SIP
, to the 2 screw terminals
located on the back of the DOOR PHONE INTERCOM. Polarity is not important.
If you plan to use the supplied connection box (supplied for use with Door or Gate Lock
Control), then the terminals for the GREEN and RED wires should be connected to the
screw terminals located on the back of the DOOR PHONE INTERCOM. Polarity is not
important.
The LED on the DOOR PHONE INTERCOM should then turn ON (
DS-SIP
must be ON).
The DOOR PHONE INTERCOM should be mounted onto your wall surface. With DP1 this is
done by separating the Door Phone unit from the integral backing plate, secured by a screw
underneath the grey plastic label, above the speaker. The backing plate should then be
screwed to the wall surface, before re-attaching the Door Phone Intercom with the securing
screw.
DP2-DP5 INTERCOMS
(4 Wire Connection)
Connect Pins 4 & 5 (the center 2 pins) of the 8 pin RJ45 socket of
DS-SIP
to the center 2
inputs of the supplied 4 position Phoenix Plug. Polarity is not important. This is the Audio
Pair.
Also c
onnect Pins 3 & 6 (the 2 pins either side of the center 2 pins) of the 8 pin RJ45 socket
of
DS-SIP
, to the outside positions of the 4 position Phoenix Plug. Polarity is not important.
This is 12V and GND for the Door Phone Intercom.
If you plan to use supplied connection box (supplied for use with Door or Gate Lock Control),
then the terminals for the GREEN and RED wires should be connected to the center 2
positions of the 4 position Phoenix Plug (pins 2 & 3) and the terminals for the BLACK and
YELLOW wires should be connected to the outer 2 positions of the 4 position Phoenix Plug
(pins 1 & 4). Polarity is not important.
LOCK CONTROL
(for 1 or 2 Locks)
A connection box is supplied with
DS-SIP
to provide a convenient means of connecting
power for the 1 or 2 Doors or Gates that will be used.
This will also allow you to locate the Power Supplies for the 1 or 2 Doors or Gates, inside the
building next to
DS-SIP
, so they are out of the weather.
See pages 10-11 for further details.