Putting into operation
24
7.7.3
Float switch
Optionally available as accesory.
Fig. 22: Float switch
(Art. 303004)
The float switch is used for pumping from one container to another one. For this
purpose, the switch is fixed to a container with the help of the vertically-adjustable
bracket.
Depending on the situation, the switch is attached straight up or upside down on the
bracket (see
Fig. 23
and
Fig. 24
). Separate instructions are provided with the float
switch.
The
manual mode
is used for operation of the float switch. The float switch operates
as in the pump options
forward
and
backward interval
.
Use upside down
(see
Fig. 23
)
- use in container which is to be emptied by pumping
- when the falling product level in the tank reaches the switch,
the float is pressed down and the motor is switched off.
- the motor runs until the tank is emptied.
- it must be ensured that the container to be filled can
accommodate the pumped quantity.
Fig. 23
Use upside down
(see
Fig. 24
)
- use in the container to be filled
- when the rising product level in the container reaches the
switch, the float is pushed up and the motor is switched off.
the motor runs until the container is full.
- overflowing of the container to be filled is prevented.
Fig 24