8
SUPERIOR RANGE OF MOTION
GERi™
/
KERi™
manikins offer the most complete and realistic range of motion with no pinch points. This allows
for correct patient positioning. The manikin’s articulation includes:
•
Trunk
— rotation, hyperextension
•
Shoulder
— abduction, adduction, rotation, hyperextension
•
Elbow
— extension, flexion, pronation, supination
•
Wrist
— flexion, hyperextension, radial flexion, ulnar flexion
•
Fingers
— abduction, adduction, flexion (soft, lifelike material)
•
Neck
— rotation, hyperextension, lateral flexion
•
Hip
— abduction, adduction, rotation, hyperextension
•
Knee
— extension, flexion
•
Ankle
— eversion, inversion, dorsiflexion, plantarflexion
•
Toes
— abduction, adduction, flexion (soft, lifelike material)
SETUP
GERi™
/
KERi™
manikins are packaged with arms and legs unattached to prevent damage during shipping.
Refer to the following sections for assembly instructions.
Arms
To attach the arms, bend the elbows backward
approximately 90° to align the keyholes at the
shoulders, and then push toward the shoulder of
the manikin. Reverse this procedure to disassemble.
(See Figure 1.)
Figure 1
Legs
The legs attach to the body at the hips by bending
the legs backward approximately 150° so the feet
are near the shoulders and the keyholes are aligned.
(See Figure 2.)
Figure 2
Head
To attach the head, position the head facing back-
wards and align the keyholes. Press down and turn
head 180° so it is facing forward. Reverse the proce-
dure to disassemble.
Joints
All joints may be assembled with a flat-head screw-
driver. Hold the opposite end of the connector pin to
prevent unproductive rotation.
Figure 3
Eyes
The eyes come installed in the head. The eyes can
be removed by creasing the skin at the outside of
each eye and rolling the eye up.
(See Figure 3.)
We
recommend you replace the eyes in the same sock-
ets, the left pupil is dilated and the right pupil con-
stricted to keep consistent with this training manual.
Both eyes may be irrigated using water. Following
completion of the exercise, follow the above instruc-
tions for removing the eye, dry the sockets com-
pletely with a soft cloth, and replace the eyes in
their respective sockets. To keep consistent with this
manual, the left pupil is dilated and the right pupil
constricted.
HC18000028INM23.indd 8