6.
DO NOT clean the simulator with solvents or
corrosive materials as they will damage it.
7.
DO NOT use for subcutaneous injection.
Nasco’s Intradermal Injection Simulator
(LF01008U) is specifically designed for intra-
dermal injection training and practice.
SUPPLIES/REPLACEMENT PARTS FOR
INJECTABLE TRAINING ARM
LF04081U
Skin and Vein Replacement Kit (Light),
LF04126U (Medium)
LF00845U
Life
/
form
®
Blood, 1 Quart
LF00846U
Life
/
form
®
Blood, 1 Gallon
LF01099U
Vein Tubing Sealant Kit
LF09919U
Nasco Cleaner
LF01130U
IV Fluid Supply Bag Set: 500 ml Supply
Bag, Tubing, Clamp and Connector
LF00996U
Vinyl Adhesive, 2 tubes (1 oz. each)
LF01117U
Butterfly Set (Pkg. of 12)
6.
After the batteries have been properly
installed, reassemble the Electronic Control
Unit by reversing the disassembly procedures.
Turning the Electronic Control Unit On
1.
Place the unit face up on the padded work sur-
face.
Figure 23
Figure 24
Power Button
16
BLOOD PRESSURE SIMULATOR ARM
(Available on Advanced and Advanced Auscultation
GERi™
/
KERi™
or as an update or add-on to all other models)
CAUTION:
PRODUCT CONTAINS DRY NATURAL RUBBER!
The Left Blood Pressure Simulator Arm has digitally recorded blood pressure sounds that can be varied by
pulse rate and volume. The different Korotkoff phases can be identified and an optional auscultatory gap
can be selected. A palpable radial pulse is present in the wrist.
GENERAL INSTRUCTION FOR USE
Installing the Batteries
1.
Take the Blood Pressure Electronic Control Unit
out of the box and turn it over, placing it face
down onto a padded work surface.
2.
Locate the “Open” compartment on the back
of the panel where the batteries are to be
installed.
CAUTIONS
1.
This synthetic blood is specially formulated to
be compatible with the self-sealing veins and
plastics used in manufacturing the injectable
training arm.
2.
NEVER use synthetic blood for intramuscular
injection.
3.
DO NOT use dull or burred needles, these will
cause leaks in the system. Burred needles will
cause permanent damage.
4.
DO NOT allow synthetic blood to dry on the
simulator — it may stain the skin.
5.
Use only 500 cc of infusion fluid. Larger
amounts will increase the pressure of the
venous system, resulting in leaks.
5.
Install 6 “AA” batteries as indicated by the ori-
entation diagram embossed in the bottom of
the bracket.
Note:
It is recommended that alkaline batteries be
used for increased battery life.
2.
Press the power button on the top right of the
unit.
(See Figure 24.)
3.
Observe the display and verify that a readable
display is present.
Note:
The control box has a battery saving feature
that will turn the unit off after approximately 8-10
minutes if no keys are used within that period of
time.
3.
Place your thumb or
index finger on the
“Open” compartment
and push up.
(See Figure 23.)
4.
This will open the bat-
tery compartment. The
compartment is marked
as to the positions of the
batteries “+” or “-”.