SETUP
A. Installing the Head
1.
Remove the head and supplies from the case. Retain any
packaging for future use.
2.
Using the #10 Spanner Bit, remove the safety cap from the
case.
3.
With the face of the manikin facing down, feed the esopha-
gus and trachea tubes through the hole in the case.
4.
Tip the head upward slightly until the two keyways on the
back of the neck slide under the ring and into the top of the
torso.
(See Figure 1.)
5.
Rotate the head until it is facing up.
(See Figure 2.)
6.
Ensure the squeeze bulb and tubing for manual carotid
pulse feature is accessible outside of the case.
(See Figure 3.)
B. Preparing the Fluid System
1.
Locate the 3-ft. tubing section with the male insert coupling
(letters G and K in the components list).
2.
Connect this tubing section to the esophagus with the
female body coupling.
(See Figure 4.)
3.
Assemble the hand pump by connecting the clear section
to the white section.
(See Figure 5.)