background image

LF00994U

  Cricothyrotomy Simulator

LF03623U

  Infant Airway Management Trainer with Stand

LF03633U

  Child Airway Management Trainer Torso

LF03672U

  “Airway Larry” with Electronic Connections

LF03685U

  Advanced “Airway Larry” Airway 

Management Trainer with Stand

LF03830U

  Adult Intraosseous Infusion Simulator

LF03685U

LF03672U

LF03633U

LF03623U

Other Available

Simulators

Copyright © 2016    HC190001INM43

ONLINE:

NascoHealthcare.com

EMAIL:

[email protected]

PHONE:

1.800.431.4310

ADDRESS: 

901 Janesville Ave. 

Fort Atkinson, WI 53538

HC190001INM43.indd   10

5/14/19   8:51 AM

Summary of Contents for LF03500U

Page 1: ...HEALTHCARE AdultAirway DecontaminationSimulator LF03500U INSTRUCTION MANUAL WARNING Products may contain dry natural rubber 5 Year Warranty HC190001INM43 indd 1 5 14 19 8 50 AM ...

Page 2: ...HC190001INM43 indd 2 5 14 19 8 50 AM ...

Page 3: ...Luke s Medical Center in Milwaukee WI uses suction to enhance first pass success laryngoscopy FPS L with a non anesthetized patient in active emesis FEATURES Airway Larry simulates a non anesthetized patient for practicing intubation ventilation and suction Anatomy and landmarks including teeth tongue oral and nasal pharynx larynx epiglottis arytenoids false cords true vocal cords trachea esophagu...

Page 4: ...the top of the torso See Figure 1 5 Rotate the head until it is facing up See Figure 2 6 Ensure the squeeze bulb and tubing for manual carotid pulse feature is accessible outside of the case See Figure 3 B Preparing the Fluid System 1 Locate the 3 ft tubing section with the male insert coupling letters G and K in the components list 2 Connect this tubing section to the esophagus with the female bo...

Page 5: ...the white fitting inside the trachea tubes D Preparing the Simulated Emesis Using the provided gallon container mix the desired amount according to the ratios below 1 quart liter of water to 3 tbsp 45 ml of cellulose 2 quarts liters of water to 6 tbsp 90 ml of cellulose 3 quarts liters of water to 9 tbsp 135 ml of cellulose Note Nasco recommends using distilled water for the mixing procedures Whit...

Page 6: ...nsure the hand pump is fastened securely 10 Connect the free end of the clear vinyl tubing from the esophagus to the spout end of the hand pump See Figure 6 11 Secure the clear vinyl tubing to the spout end of the hand pump with a small pinch clamp Note Depressing the hand pump allows for approxi mately 1 tbsp 15 ml of simulated emesis per pump E Preparing the Suction System Note This system is de...

Page 7: ...uth area if stu dents will be applying direct mouth to mouth resuscitation techniques as the cleaner may be toxic if ingested B Cleaning the Airway Management Trainer 1 Disconnect the fluid system 2 Suction any remaining simulated emesis from the Airway Larry head Note Simulated emesis can be reused and stored in the gallon container if desired During storage ensure the cap is on securely Do not s...

Page 8: ...t head and intubation appliances Use only Nasco Pump Spray Lubricant LF03644U with this simulator Other lubricants such as silicone oil may cause damage to the airway of the simulator Ensure intubation appliances are used accordingly Improper use of intubation appliances could damage the airway of the simulator Damage to the airway will require the product to be returned to Nasco for repair Ensure...

Page 9: ...nections LF03685U Advanced Airway Larry Airway Management Trainer with Stand LF03830U Adult Intraosseous Infusion Simulator LF03685U LF03672U LF03633U LF03623U Other Available Simulators Copyright 2016 HC190001INM43 ONLINE NascoHealthcare com EMAIL lifeform enasco com PHONE 1 800 431 4310 ADDRESS 901 Janesville Ave Fort Atkinson WI 53538 HC190001INM43 indd 10 5 14 19 8 51 AM ...

Reviews: