E8 Swing Automatic Gate. Revision 1.1.8 –1112
11 of 19
Single Gate Operation:
1. Set
DIP
switch
[5]
to
ON
position and connect arm motor wires to [MT A]
terminals.
2. Place / Connect both receiver output wires together (Yellow and Brown) into
the far right terminal [1 SIDE].
3. Place receiver common wire (White) into the [COM] terminal.
Note:
Do NOT have any connection to [2 SIDE] terminal as this will confuse the
board and Motor B will not cut off.
4. Set the ARM in the CLOSE position and then power up the board.
5. Press the remote transmitter and observe GREEN Led indicating Opening
cycle on D1 board. Gate is running on Slow Speed. If it is RED then switch
OFF power and reverse the motor wire polarity to change the direction of the
motor. Return to step 3.
6. Board auto cutoff when high amp. GREEN Led will go off.
7. Press transmitter again. Gate should close. Observe the RED Led indicating
Closing cycle
8. In the 1 Arm operation, gate when fully closed (at high speed) the first time,
may reopen. This is ok.
9. Press the Transmitter again. Observe the RED Led indicating closing cycle.
10. When the gate is stopped, the RED Led will go off.
The system has now stored the range between opening and closing time. The
microprocessor will automatically adjust the low speed and high speed opening /
closing of the system.
Setup is now complete.
7. Test each cycle a few times to make sure the microprocessor has stored the
correct range.
2 SIDE
COM
1 SIDE
NO
Connection to
[2 SIDE]
terminal for
Single Arm
Receiver (COM)
Parallel Yellow and
Brown wire of
Receiver to [1 SIDE]