E8 Swing Automatic Gate. Revision 1.1.8 –1112
10 of 19
Setting the System :
Double Gate Operation (Both Pull-to-Open and Push-to-Open Gate)
1. Unplug AC power
and
Battery and make sure the gate(s) are
completely
CLOSED
.
2. After 30 seconds reconnect power to the system until short clicking from
board can be heard.
3. Press remote transmitter for gate(s). Let the motor open (low speed) until
gate(s) are fully opened. Check that the [MT A] and [MT B] LEDs are
green
.
If red LED is observed, disconnect power then reverse arm wire in question
and start setup again from step 1.
4. Both the motor will stop automatically when the gate is hard stopped. High
current cut-off by the circuit board is automatically achieved.
5. Press remote transmitter again and let the motor close (high speed) until both
gates are fully closed. [MT A] and [MT B] LEDs are
Red
. Both the motor will
stop automatically when the gate is hard stopped. High current cut-off by the
circuit board is automatically achieved.
The system has now stored the range between opening and closing time. The
microprocessor will automatically adjust the low speed and high speed opening /
closing of the system.
Setup is now complete.
6. Test each cycle a few times to make sure the microprocessor has stored the
correct range.
Note that :
The gate will auto reverse when the system detects obstruction (high
amp) during high speed closing operation.
The gate will stop when the system detects obstruction (high amp)
during opening operation.
To Reset :
To RESET the Memory, remove all power sources (Mains and
Battery). Wait for 30 seconds. System will reset the open / close
calibration. Repeat Step #1 – 5 to set the memory.
Note :
For Pull to Open Gate – Arm is fully extended in the gate-close position
For Push to Open Gate – Arm is fully retracted in the gate-close position