background image

-  Once the heater has been set, the set values will remain in memory, and when power is switched 

  on via the I/O button, the heater will always be warmed up in the same way for the same set period 

  of time. The preset time, however, will always be zero.  If you wish to apply the preset timing 

  feature, you will always need to activate it separately.

-  If the SET button is not pressed after the setting, the LED will continue flashing for about one

  minute. After this, the heater will automatically return to its normal operating mode, and the settings 

  will be saved in memory.

4.7 Display settings

-  In the normal operation mode of the heater, the parameters to be displayed can be selected 

  as follows: In the normal operation mode, keep the + and - buttons simultaneously depressed 

  for more than three seconds. On the display is shown ”d 1”. Now, by pressing the + and - 

  buttons one by one, you can switch between three different display modes: ”d 1”,”d 2” and ”d 3”.

  - 

”d 1”: The temperature of the sauna is shown on the display

  - 

”d 2”: The remaining power-on time is shown on the display

  - 

”d 3”: The temperature of the sauna (the red LED is on) 

   

and the remaining power-on time (the green LED is on) are alternating on the display.

-  After having selected the display mode, return to the normal operating mode by 

  depressing the SET button.

-  If the SET button has not been depressed after the setting, ”d” and the number of the selected 

  display mode will remain on the display for about one more minute. After this, the heater will 

  automatically return to its normal operating mode, and the settings will be saved in memory.

-  The display mode setting will stay in the memory despite outage of the power.

-  During pre-timing, is always displayed the remaining preset time.

4.8 Examples

The desired temperature in the sauna is about 100 °C and 

the heater is desired to be switched on for 2.5 hours at a time.

1.  Switch on the power using the I/O button.

2.  Depress the SET button -> the yellow LED flashes.

3.  Depress the SET button a second time -> the green LED flashes.

4.  Depress the + or - button several times until the reading 2:30 is displayed.

5.  Depress the SET button  -> the red LED flashes.

6.  Depress the + or – button several times until the sign 100°C is displayed.

7.  Depress the SET button -> the heater is switched on and the set values will be saved 

  for the next time.

You wish to switch on the heater in about three hours

1.  Switch on the power using the I/O button.

2.  Depress the SET button  -> the yellow LED flashes.

3.  Depress the + or – button several times until the reading 3:00 is displayed.

4.  Depress the SET button -> the green LED flashes.

5.  If you want to keep the set power-on time, depress the SET button; to change the power-on time,

  use the + or - buttons.

6.  After the SET button is depressed, the red LED will flash. If you wish to set the temperature, 

  you can use the + or - buttons; if not, just depress the SET button to turn the heater on.

The remaining power-on time is only 15 minutes, but you wish to continue enjoying the sauna for 

longer than this

1.  Depress the SET button -> the green LED flashes, the remaining power-on time will still be displayed.

2.  Select the desired additional time by depressing the + button

3.  Depress the SET button -> the red LED flashes.

4.  Depress the SET button -> the heater will remain switched on for the time indicated on the display.

5.  Note!  After the desired period of time has been set, the green LED can be left flashing.

  The heater will then automatically return to its normal operating mode within about 1 minute.

Summary of Contents for SMOOTH 9kW

Page 1: ...NARVI SMOOTH 6 8kW 9kW 10 5kW FI SE EN DE RU ASENNUS JA K YTT OHJE INSTALLATIONS OCH BRUKSANVISNING INSTALLATION AND INSTRUCTION MANUAL INSTALLATIONS UND BETRIEBSANLEITUNG VERSIO 09 2017...

Page 2: ......

Page 3: ...ukeva kiinnitysalusta Pelkk ohut paneeli ei riit Vahvistuksena voi olla lis koolaus paneelin takana tai paneelin p ll vahvikelaudat jotka kiinnittyv t sein koolaukseen Kiukaan alla tulee olla kuumuutt...

Page 4: ...a kiuas voi ylikuumentua Jos kiuas asennetaan kauemmas kuin 200 mm et isyydelle sein st on anturi asennettava kattoon 100 mm sivuun kiukaan ulkopinnasta Asenna l mp tila anturi sein lle mukana tulevil...

Page 5: ...n mahdollisimman tiiviisti niin etteiv t vastukset n y Kiuaskivien tarkistus ja uudelleen asettelu pit isi suorittaa 1 2 vuoden v lein ja kivet uusittava 2 3 vuoden kuluttua Vuolukivet tai keraamiset...

Page 6: ...intaansa siit pisteest miss se oli ennen katkoa Jos katko on yli 3 min kiuas menee pois p lt Asetusarvot s ilyv t aina muistissa s hk katkon pituudesta riippumatta 4 6 Asetukset Kun kiuas laitetaan p...

Page 7: ...oleva esiajastusaika 4 8 Esimerkkej Haluttu saunomisl mp tila on noin 100 C ja kiukaan halutaan olevan kerrallaan p ll 2 5 tuntia 1 Kytket n virta I O napista 2 Painetaan SET nappia keltainen led vilk...

Page 8: ...AUNAN RAKENNE Saunan tulee olla hyvin l mp eristetty varsinkin katto josta eniten l yly pyrkii poistumaan Kosteuden vuoksi suositellaan saunan l mp eristeet suojaamaan kosteutta l p isem tt m ll esim...

Page 9: ...yn merkinn t ON OFF N L F1 400mA TR1 K6 K3 K1 K4 K2 K5 K7 K8 K9 VA3N N3 VA2N N2 VA1N N1 L2 VA2L CTL L3 VA3L L1 X1 B1 B2 A1 A2 X2 2 3 4 5 1 6 VA1L 1A 2A 4B 5B 5 4 3 2 1 6 12V NTC CTL CLK YLS K1 A1 A2 B...

Page 10: ...ilt Takuu ei korvaa ulkopuolisten h iri iden aiheuttamaa sulakkeen hajoamista Ohjaimen johto on vaurioitunut tai kontakti on huono ohjaimen liitoksissa Ohjaimen kotelo on v ntynyt esim kiinnityksen ta...

Page 11: ...s i tabell 1 f r varken verskridas eller underskridas Tabell 1 Installationsdata f r aggregat Bastuns minimih jd samt minimis kerhetsavst nden anges i tabell 1 F rs kra dig om att f stunderlaget f r f...

Page 12: ...r n 200 mm bort fr n v ggen m ste temperatursensorn placers i taket s att den ligger 100 mm bort t fr n aggregatets yttre kant F st temperaturgivaren p v ggen med medf ljande skruvar 2 st 2 9 x 16 Tem...

Page 13: ...s att motst nden inte syns Bastustenarna b r kontrolleras och omstaplas med ett halvt rs mellanrum och stenarna skall bytas ut efter 2 3 r Mjuk t ljsten och keramiska stenar l mpar sig inte f r det h...

Page 14: ...n var innan avbrottet gde rum Om avbrottet p g r ver tre minuter sl s bastuaggregatet av St llv rdena sparas i minnet oavsett elavbrottets l ngd 4 6 Inst llningar Medan bastuaggregatet r p slaget kan...

Page 15: ...dtemperaturen r ca 100 C och du nskar att bastuaggregatet vid varje anv ndningsg ng h lls p kopplat i 2 5 timmar 1 Koppla p str mmen via knappen I O 2 Tryck ner knappen SET den gula diodlampan blinkar...

Page 16: ...rummet via tv ttrummet exempelvis under d rren ppning mellan d rrens underkant och golvet ska vara ca 100 150 mm Om basturummet f rses med en skild f rtorkningsventil ska den placeras i basturummets t...

Page 17: ...av barn eller s dana personer vilkas fysiska och psykiska egenskaper sinnesfunktioner brist p erfarenhet eller kunskap kan utg ra ett hinder f r en trygg anv ndning av aggregatet om den person som an...

Page 18: ...or som orsakats av externa orsaker Controllerns kabel kan vara skadad eller felaktigt kopplad Controllers plastfodral har g tt s nder t ex vid installeringen Knapparna fungerar inte eller r nedtryckta...

Page 19: ...n table 1 Table 1 Installation information for heaters The minimum height of the steam room and minimal safety clearances are shown in table 1 Make sure that the surface onto which the fastening plate...

Page 20: ...sor must be placed into the ceiling 100mm away from the heaters outer surface Install the temperature sensor on the wall with the screws included in the delivery 2 pcs 2 9 x 16 The wiring for the temp...

Page 21: ...one or ceramic stones are not suitable for this heater The heater stones should be inspected and repositioned every 6 months and the stones should be replaced every 2 3 years DO NOT USE THE SAUNA HEAT...

Page 22: ...e the outage If the outage lasts longer than three minutes the heater is switched off The settings will always stay in the memory despite duration of the outage 4 6 Settings When the heater is switche...

Page 23: ...ge of the power During pre timing is always displayed the remaining preset time 4 8 Examples The desired temperature in the sauna is about 100 C and the heater is desired to be switched on for 2 5 hou...

Page 24: ...f the steam room through the washroom for instance under the door There must be an approximately 100 150 wide slit between the door and the floor If you provide your sauna with a separate drying valve...

Page 25: ...e after the heater is heated a few times Do not connect the power supply for the electric heater through a fault current protection The location of the connectors in the wiring diagram is indicative S...

Page 26: ...ire may be damaged or it has a bad connection The control units casing has been damaged for example if it is installed incorrectly Buttons does not work or are pressed down constantly Open the lid and...

Page 27: ...formationen zum Aufbau von fen Die Mindesth he des Saunaraums sowie die Mindestsicherheitsabst nde werden in Tabelle 1 dargestellt Stellen Sie sicher dass die Oberfl che auf der die Befestigungsplatte...

Page 28: ...d montiert wird muss der F hler an die Decke und 100 mm seitlich versetzt vom Au enmantel des Ofens montiert werden Befestigen Sie den Temperaturf hler mit den beigef gten Schrauben 2 St 2 9 x 16 an d...

Page 29: ...uss allerdings m glichst dicht sein damit man die Heizwiderst nde nicht sieht Die Steine im Saunaofen m ssen alle 6 Monate berpr ft und neu geschichtet sowie alle 2 3 Jahre erneuert werden Keramische...

Page 30: ...befunden hat Wenn die Unterbrechung l nger als 3 min dauert dann schaltet sich der Saunaofen aus Die Einstellwerte bleiben allerdings unabh ngig von der Unterbrechungsdauer gespeichert 4 6 Einstellun...

Page 31: ...Die gew nschte Saunatemperatur ist ca 100 C und der Saunaofen soll 2 5 Stunden lang heizen 1 Schalten Sie mit dem I O Taster ein 2 Bet tigen Sie die SET Taste die gelbe LED blinkt 3 Bet tigen Sie die...

Page 32: ...ken befinden Die aus dem Dampfraum hinausstr mende Luft kann durch den Waschraum geleitet werden zum Beispiel unter der T r hindurch Zwischen T r und Boden muss sich ein ungef hr 100 150 mm breiter Sc...

Page 33: ...Aufsicht oder Anleitung der f r die Sicherheit zust ndigen Person geschehen Gehen Sie nicht in die Sauna wenn Sie unter dem Einfluss berauschender Substanzen sind Kinder d rfen sich nicht ohne Aufsich...

Page 34: ...den Saunaofen vor St rungen im Stromnetz Die Garantie gilt nicht f r Besch digung der Sicherung aus u eren Ursachen Das Steuerkabel ist besch digt oder der Kontakt in den Anschl ssen ist schlecht Das...

Page 35: ...10 5 RU 1 1 2 3 4 5 2 3 1 1 5 3 1 1 1 1 5 10 400 V 3N A B C D 3 3 2 A Smooth 6 8 6 8 5 8 190 10 10 70 3 100 5x1 5 3x10 Smooth 9 9 8 14 190 10 10 70 3 100 5x2 5 3x16 Smooth 10 5 10 5 10 18 210 10 10 9...

Page 36: ...3 3 1 H07RN F 7 1 3 11 2 3 12 100 1 1000 500 1000 200 100 2 2 9 x 16 6 1 P 2 D min A min min 600 B min max 900 100 C min A min A min A min 3 13...

Page 37: ...3 2 VELVET 3 1 5 10 1 2 2 3 4 4 5 ON OFF SET P 3 P 4 90 60 1 2 3 5 15 3 0 10 20...

Page 38: ...4 1 I O SET ON OFF ON OFF 4 2 60 C 115 C 4 3 ON OFF 15 4 4 15 4 5 ON OFF ON OFF 3 3 3...

Page 39: ...4 6 1 SET 30 SET SET SET 60 C 115 C SET ON OFF ON OFF I O SET 1 4 7 3 d 1 d 1 d 2 d 3 d 1 d 2 d 3 SET SET 1 d...

Page 40: ...6 100 5 5 1 60 C 115 C 24 4 5 2 IPX4 5 3 230 3 50 16 A 10 5 IPX4 144 C 400 4 8 100 C 2 5 1 I O 2 SET 3 SET 4 2 30 5 SET 6 100 C 7 SET 3 1 I O 2 SET 3 3 00 4 SET 5 SET 6 SET SET 15 1 SET 2 3 SET 4 SET...