INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 9
4.4 Connection to power supply
IMPORTANT: This machine must be connected to a single outlet with earthing
The MX700 is equipped with a three phased engine 230V / 400V with 5,5Kw connected on a star shape to
connect into a power supply of 400V. It should be connected to an only power supply with the indicated
requirements. If the line tension is not the indicated one then there must be carried out a change of
connection of the motor bobins and the inverter as indicated in the following pictures:
Picture 9
Picture 10
In case of change of tension from 400V to 230V, change terminal 6 from 400V and put it in terminal 230V.
Picture 11
Star picture
(preset)
For tension 400V
Triangle picture
For tension 230V
Fuse of 0,5A
Fuse of 4A
Summary of Contents for MX700
Page 2: ...Thank you for choosing our machines www nargesa com ...
Page 28: ...Technical annex Hydraulic punching machine MX700 List of parts Electric maps Hydraulic map ...
Page 29: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A2 A1 List of parts ...
Page 30: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A3 ...
Page 31: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A4 ...
Page 32: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A5 ...
Page 33: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A6 ...
Page 34: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A7 ...
Page 35: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A8 ...
Page 36: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A9 ...
Page 37: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A10 ...
Page 38: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A11 A2 Electric maps ...
Page 39: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A12 ...
Page 40: ...INSTRUCTION BOOK HYDRAULIC PUNCHING MACHINE MX700 A13 A3 Hydraulic map ...