PACIFIC D23
28 |
P a g e
PACIFIC D23
Nardi Compressori – www.nardicompressori.com
7.22
TROUBLE-SHOOTING:
PROBLEM
CAUSE
REMEDY
The air delivery decreases (without
lowering the rotation speed)
•
Loose fittings
•
Tighten fittings
•
Worn gaskets
•
Replace the gaskets
•
Intake filter clogged
•
Replace or clean filter
•
Worn piston rings
•
Replace piston rings
•
Intake extension clogged
•
Check intake extension tube
•
Valves not working
•
Replace or clean valves
Compressor does not reach
•Worn piston rings
•
Replace worn piston rings
maximum presure
•Excessively worn pistons
•
Replace worn pistons
•Premature opening of safety valve
•Clean safety valve
•Check and correct calibration of safety valve
•Replace safety valve
The safety valve of an intermediate
stage has a leak
•
Stage pressure too high
•
Pressure problems in next stage
•
Premature opening of safety valve
•
Clean safety valve
•
Check and correct calibration of safety valve
•
Replace safety valve
Compressor overheating
•Wrong sense of rotation of motor
•Invert the phase of the electric motor
•Poor air intake
•Increase air intake in the room
•Valves not closed properly
•Check, clean and replace valve
•Ambient temperature too high ( +45 °C Max)
Breathing air smells of oil
•
Final filter cartridge exhausted
•Replace final filter cartridge
Excessive oil consumption
•Worn piston rings
•Replace worn piston rings
•Excessively worn piston
•Replace worn piston
•Intake filter clogged
•Clean intake filter
•Replace intake filter
The compressor does not switched
off automatically
•Solenoid valve calibration too high
•Correct the calibration of the solenoid valve
•Safety valve of last stage not working
•Clean safety valve
•Calibration safety valve
•Replace safety valve