background image

5

INSTALLATION

The framing dimensions are included in the framing specifications drawing. The unit is designed to be installed after drywalling.

For added protection water resistant drywall (green board) or cement board are recommended in the vicinity of the fountain. The
fountain is designed to be attached to the studs over the drywall along both vertical sides of the fountain using drywall screws. This
will leave a basically flush surface to trim over. Leak test the waterfall before fully enclosing. All trim used on the fountain should be
made of real wood (not MDF), or any other material that is not damaged by moisture, with several coats of a water proof coating
(paint or urethane) depending on the desired look. The bottom piece of trim can only be nailed at the ends, because it is mounted
in front of the stainless basin. It should be siliconed to the stainless basin for additional support.

After installing the fountain, connect the piping as shown in the piping diagrams. The tubing to connect the unit overflow to the

house drain is not supplied. If the unit is being connected to the water supply, use an ice maker plumbing kit (not supplied) to
connect the water supply to the float valve. When the unit is operational, adjust the float valve so that it turns the water off when the
top of the pump is submerged below 1-2” of water. Ensure that the wing nut on the side of the float valve is properly tightened.
Connect the light wire to the terminals on the transformer.

WATERFALL SURFACE MATERIALS

The waterfall models WF6, WF9, and WF18 are supplied with a stainless steel panel for the water to flow over. The surface of

the stainless steel must be cleaned to remove any grease or oily materials left behind from the manufacturing process. The protec-
tive coating will also leave a residue behind. Any residue left on the surface, or oily residue from your hands, will repel the water
and prevent a sheet of water from forming over the panel. This will give you thin streams of water with large dry spots in between.
Cleaning the panel with liquid TSP (or TSP Substitute) will remove any residue or film that is impeding the progress of the water.
Clean the panel thoroughly two or three times before the first use.

The See-Thru waterfall model is not supplied with any surface panel. The glass panel can be ordered from any glass and window

dealer in your local area. There is no specific type of recommended glass, but the glass should be 1/4” thick. Clear glass displays
the water flow pattern the best, but if privacy between the adjoining rooms is desired some type of smoked or opaqued glass will
work as well.

Before starting the waterfall, the entire panel surface should be wet down, either by spray bottle, or wet cloth. This will help the

water to spread evenly across the panel. The wave effect of water flowing down the panel, will be attained after the panel is covered
in water. The wave pattern can be adjusted by increasing or restricting the flow of water with the valve at the side of the filter. Adjust
the valve to achieve the effect that is most pleasing to your eye. It is important to remember that too little water flow can cause dry
spots to reappear on the surface of the waterfall. You can increase the flow of water slightly until they disappear. Lightly rubbing a
wet cloth or Scotchbrite pad (careful not to scratch the stainless steel surface), across the panel may be enough to remove any dry
spots.

GROOVED LUXIDIO PANEL: An optional grooved LUXIDIO panel which enhances the ripple effect can be purchased at your

authorized NAPOLEON dealer. This panel must be cleaned with liquid TSP (or TSP Substitute) before being placed in the unit, to
prevent dust and debris from the manufacturing process from entering the water. Use caution when cleaning the grooves on the
panel as the machined edges can be very sharp. The stainless steel panel must be removed before installing the LUXIDIO panel.
Turn off the water before switching the panels. To remove the stainless steel panel, slide it upwards slightly, then swing the bottom
of the panel towards you, clearing the panel retaining brackets. Slide the panel downwards and out of the fountain. Install the
LUXIDIO panel in the reverse order. The LUXIDIO panel will require more water to achieve the same wave effect as the stainless
panel, as the grooves will fill and retain water. Again any dry spots can be removed by rubbing horizontally with a Scotchbrite pad.

VALVE

FULL OPEN

VALVE

PARTIAL OPEN

FROM BASIN

TO FOUNTAIN

FROM BASIN

TO FOUNTAIN

TO DRAIN

TO DRAIN

Summary of Contents for WF 18

Page 1: ...R NAPOLEON APPLIANCE CORP 214 BAYVIEW DR BARRIE ONTARIO CANADA L4N 4Y8 PHONE 705 726 4278 FAX 705 725 2564 EMAIL ask nac on ca WEB SITE www napoleongrills com RETAIN THIS MANUAL FOR FUTURE REFERENCE G...

Page 2: ...first year only this warranty extends to the replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation...

Page 3: ...urally and will require additional water to ensure proper flow and pump operation Damage to the pump incurred by running dry is not covered by warranty The waterfall must be hooked up to a drain which...

Page 4: ...everse Osmosis water will give the best results and require the least amount of maintenance If the unit is not being connected to the house supply distilled bottled water is recommended The provided f...

Page 5: ...el thoroughly two or three times before the first use The See Thru waterfall model is not supplied with any surface panel The glass panel can be ordered from any glass and window dealer in your local...

Page 6: ...Install the tube cover and test the unit CUSTOM SURFACE PANEL Panels can also be made using materials such as mirror glass slate marble or ceramic tile for display in your waterfall If tiling use wat...

Page 7: ...D40 rag to repel water TROUBLESHOOTING Drain is gurgling Insufficient drop from fountain to basin Ensure there is at least 1 per foot drop from the fountain outlet to the basin inlet P trap created in...

Page 8: ...n is not sufficient 4 Proof of purchase photocopy of the invoice In some cases the customer service representative may request to have the parts returned to the factory for inspection before providing...

Page 9: ...RYWALL BELOW THE UNIT SHOULD CONTINUE UP TO THE BOTTOM OF THE WATERFALL BASIN Additional height may be required to ensure adequate drop to the pump module The minimum space required for the pump modul...

Page 10: ...A B A TO DRAIN CUT THE SHORT PIECE OF BLACK TUBING TO 14 SADDLE VALVE NOT INCLUDED SEDIMENT FILTER INSTALL THE SUPPLIED HOSE CLAMPS ON EITHER SIDE OF THE BASIN FLOW CONTROL VALVE PURGE VALVE Remove c...

Page 11: ...the filter and basin When using the optional UV light the barbed elbow fitting on the IN side of the filter will need to be removed and threaded into the elbow at the bottom of the UV light Then conne...

Page 12: ...w ay valve x 26 n255 0041 n255 0041 n255 0041 n255 0041 3 4 male pipe to 1 2 barb adapter fitting x 27 n350 0052 n350 0052 n350 0052 n350 0052 sediment filter housing x 28 n252 0001 n252 0001 n252 00...

Page 13: ...13 PARTS DIAGRAM...

Reviews: