EN
W415-2355 / A / 12.09.20
5
standard checklist
1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m) .
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
Provide adequate accessibility clearance for servicing and operating the appliance.
Never obstruct the front opening of the appliance.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can
be improved if the assembly is warmed, using a hair dryer or similar heat source. The protective wrap must be
removed before operating the appliance.
This appliance is a decorative product. It is not a source of heat, not intended as a heating appliance,
and not for use with solid fuel.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales.
Certaines piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Rensei-
gnez-vous auprès de votre municipalité au sujet des directives de recyclage.
Las baterías deben desecharse de acuerdo con las leyes y regulaciones locales. Algunas baterías
pueden reciclarse, y es posible que su centro de reciclado local las acepte para desecharlas.
Consulte en su municipalidad sobre las instrucciones para el reciclado.
1.1 rates and efficiencies
GD19-2
NATURAL GAS
PROPANE GAS
Altitude (FT)
0 - 4,500
0 - 4,500
Maximum Input (BTU/hr)
11,500
11,000
Maximum Output (BTU/hr)
8,600
8,250
Minimum Inlet Gas Supply Pressure
4.5" (11mb) Water Column
11" (27mb) Water Column
Maximum Inlet Gas Supply Pressure
7" * (17mb) Water Column
13" (32mb) Water Column
Manifold Pressure Under Flow Conditions
3.5" (9mb) Water Column
10" (25mb) Water Column
Installer, please fill out the following information:
Customer: ________________________________________________________________________
Address: ________________________________________________________________________
Date of Installation:
________________________________________________________________________
Location of Appliance:
________________________________________________________________________
Installer:
________________________________________________________________________
Dealer/Distributor contact number: ________________________________________________________________________
Serial
#:
________________________________________________________________________
Model:
Natural Gas:
GD19N-2
Propane:
GD19P-2
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appli-
ance and must be installed.
* Max. inlet pressure not to exceed 13".